FLUID DRAINS
Water contained in pneumatic systems will be collected in the filter housing bowls. These bowls must therefore be drained regularly.
The system includes 2 manual drains beneath the filtration assemblies. Fluids can be drained by turning the drain valve anti-clockwise when
the system is unpressurised. The drain is closed again by turning the valve clockwise.
COMPRESSOR
For the Clearflow 3 system to provide breathable quality air, it is important that the compressor, or its air inlet, is situated in a clean,
uncontaminated environment (usually outside, away from sources of contamination such as traffic fumes, chemicals, confined spaces, etc.).
The compressor must be inspected and serviced regularly, and its filters changed following the manufacturer's instructions.
MAXIMUM FLOW RATE CAPACITY
The Clearflow 3 system can supply breathable air for up to 4 operators using facemasks, or up to 2 operators using facemasks at the same
time as additional tools such as hand-held paint spraying equipment.
SPARE PARTS (Figure 1)
Item
Part number
1
1763341
Isolating valve
2
1763923
Wall mounting bracket for regulator
3
1763922
Ring for regulator mounting bracket
4
1763926
Filter head connector (with 2 O-ring gaskets)
5
1763925
Filter head connector with wall bracket (with 2 O-ring gaskets)
1763924
5 O-ring gaskets
6
1763921
Filter blocking indicator (available as a service/repair kit)
7
1763914
Regulator (complete, without pressure gauge)
8
1001707
Pressure gauge
9
1001722
Quick connector (CEJN for Airvisor)
9
1763420
Quick connector (RBE 06)
9
1763422
Quick connector (AQR 06)
9
1763920
Quick connector (double-action for Airvisor 2 DHC)
10
1763928
Coalescing filter assembly (complete, supplied with connector)
1763908
Coalescing filter
11
1763916
Activated carbon filter assembly, complete
1763907
Activated carbon filter element
12
1763927
Filter housing bowl (with manual drain)
13
1017050
Skid (complete with fixing bolts)
1005060
Connecting kit for Airvisor (includes a 'Y' piece + one CEJN connector)
1763335
RBE connecting kit (includes a 'Y connector + one RBE 06 connector)
1763333
AQR connecting kit (includes a 'Y connector + one AQR 06 connector)
1763929
Dual action connecting kit (includes a 'Y connector + one dual action connector)
WARNING
The Clearflow 3 system does not remove CO or CO
Description
EN-2
2