English
Reassemble the thermometer in reverse
order, noting the correct tightening torque
of 0.4 Nm.
To ensure device is fully water-tightness,
make sure the seal between lower and
upper housing is seated correctly in the
groove.
Finally, do not forget to insert both plastic
plugs back into their drill-holes (slightly
chamfered surfaces outward).
Avoid any electrostatic discharging
during the battery replacement
process.
9 Appendix
I
Accessories
Description
Artificial leather case, long
Portable case
Protective casing
Synthetic material mount
Logger holder, stainless steel AG160
Battery changing set
Probes in various specs available on
request.