3. Vapor Removal From Cooking Equipment, NFPA-96 (latest edition). Copies may be obtained from
The National Fire Protection Association, Batterymarch Park, Quincy, MA 02169-7471.
4. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National
Fire Protection Association, Batterymarch Park, Quincy, MA 02169-7471.
In Canada:
1. Local codes.
2. CSA B149.1 Natural Gas and Propane Installation Code.
3. CSA C22.1 Canadian Electric Code (latest edition).
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.
INSTALLING BASIC OVEN
The basic oven must be installed on legs or be mounted on a
modular stand. Installations on concrete bases or other supports
restricting air circulation underneath the oven is not advisable and
may void the warranty.
Ovens Mounted on Casters
Ovens mounted on casters must use a flexible connector (not
supplied by Vulcan) that complies with the Standard for Connectors
for Movable Gas Appliances, ANSI Z21.69 • CSA 6.16 and a
quick-disconnect device that complies with the Standard for
Quick-Disconnect Devices for Use With Gas Fuel, ANSI-Z21.41
• CSA 6.9. In addition, adequate means must be provided to limit
movement of the appliance without depending on the connector
and the quick-disconnect device or its associated piping to limit
appliance movement. Attach the restraining device at the rear of
the oven as shown in Fig. 1.
Remove two screws from the rear of the oven and install the tie-down strap shipped with the casters using
these screws (Fig. 1). Attach the gas line strain relief to the tie-down strap at the rear of the oven (Fig. 1).
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this
restraint prior to turning the gas supply on and returning the oven to its installation position.
Separate instructions for installing casters to the oven are included with the casters.
Note: If the oven is installed on casters and is moved for any reason, it is recommended that the oven
be releveled front to back and side to side.
STRAIN RELIEF
– 5 –
CONNECT
GAS LINE
HERE
Fig. 1
PL-53563