Wind Air Kit - Forced Ventilation Components/Excluding Diffusers; Wind-Air.-.Diffusers - LA NORDICA KIT WIND AIR Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

WIND AIR KIT - FORCED VENTILATION COMPONENTS/EXCLUDING DIFFUSERS

OPTIONAL. ventilation. kits. can. be. installed. on. our. products. to. improve. the. distribution. of. heat. through. ventilation. of. the. installation.
environment.or.the.adjacent.room.
The.Wind.Air.Kit.consists.of.two.vents.for.forced.ventilation.fitted.with.a.fan,.a.temperature.probe.and.a.regulator.that.controls.the.two.fans.
of.the.air.vents.at.the.same.time.
Ignition and regulation are managed by the dedicated regulator supplied which must be installed far away from direct heat sources.
The.probe.installed.in.one.of.the.two.ventilation.outlets,.in.addition.to.controlling.the.ventilation.in.AUTOMATIC.mode,.performs.a.SAfETY.
control.by.operating.the.two.fan.motors.when.the.air.temperature.exceeds.the.maximum.permitted.value.
Code 6016030
7
1
2
1.-.Motor.group.(no.2.pieces)
2.-.Regulator.(no.1.piece)
3.-.Regulator.wall.box.(no.1.piece)
4.-.Zinc-coated.connector.(no.2.pcs).for.
pipe.ø120mm
WIND-AIR - DIFFUSERS
NOT INCLUDED IN THE WIND AIR KIT. TO BE ORDERED SEPARATELY!
SHADE.diffuser.for.WIND-AIR.system.with.fixed.regulation.
Code.6016005.-.0,25.kg
1
3
5.-.Galvanised.angular.element.for.motor.group.fixing.
(no.2.pieces)
6.-.Pipe.clamp.band.stainless.steel.D.60.-175.mm.
(no.4.pieces)
7.-.Stapled.aluminium.pipe.D.120.mm.-.L.min.0,5.m,.
L.max.1,5.m.(no.2.pieces).*
WAVE diffuser.for.WIND-AIR.system.with.fixed.regulation.
ENGLISH
6
4
*
longer distances involve the creation of an extension by the installer !
Code.6016025.-.0,90.kg
10
5
8.-.Motor.electric.wiring.(no.2.pieces)
9.-.Temperature.probe.with.electrical.
cable.2.5.m.*
10 -.Adhesive.gasket.20x2mm.-.2,4m
9
8
25

Publicité