PHOTO E
DC 24V MODEL WITHOUT TRACTION
1
BRUSH MOTOR SWITCH
2
SUCTION MOTOR SWITCH
3
BATTERY POWER TEST
PHOTO F
AC 230V MODEL
1
GENERAL ON/OFF SWITCH
2
BRUSH MOTOR SWITCH
3
SUCTION MOTOR SWITCH
PHOTO G
DC 24V MODEL
1
SUCTION COMPARTMENT HOOD
2
BATTERY COMPARTMENT WITH 12V
BATTERIES
3
BATTERY COMPARTMENT HOOD
PHOTO H
DC 24V MODEL
1
SUCTION FILTER
2
VACUUM MOTOR COMPARTMENT
PHOTO I
DC 24V MODEL
BATTERY CONNECTION DIAGRAM
PHOTO L
1
SUCTION HOSE CONNECTOR
2
SQUEEGEE INCLINATION ADJUSTING
KNOB
3
SQUEEGEE BLADES REPLACEMENT
KNOB
4
SQUEEGEE BUMPER WHEEL
5
SQUEEGEE PRESSURE ADJUSTING
KNOB
6
SQUEEGEE WHEEL
7
SQUEEGEE FIXING KNOB
PHOTO M
1
SPLASH GUARD FIXING SPRING CLIP
2
SPLASH GUARD
PHOTO M
1
BRAKE LEVER
5.2.2 BATTERY
If supplied, the Pb-Acid (if not dry charged) or gel
batteries are ready to be installed:
Positive pole - red
Negative pole - black
5.2.3 BATTERY CHARGER
If supplied, refer to the corresponding booklet.
5.3 ACCESSORIES
Your machine supplier can provide a complete and
updated list of all available accessories, such as
brushes, scrapers, disks, etc.
6. INSTALLATION INFORMATION
6.1 BATTERY PREPARATION
!
(
) The technical features of the batteries used
must match those indicated in the technical featu-
res section. Using different batteries may cause se-
rious damage to the machine or may require them
to be charged more frequently.
(
) During installation or when performing any
type of battery maintenance, the operator must be
equipped with adequate safety accessories to pre-
vent accidents. Work far from open flames, do not
short-circuit the battery poles, do not generate
sparks and do not smoke.
The batteries are normally supplied full of acid so-
lution (for the Pb-Acid type) and ready for use. In
any case, follow the steps indicated in the manual
supplied with the battery and carefully follow the
instructions regarding safety and operating proce-
dures.
6.2 BATTERY INSTALLATION AND PREPARA-
TION
!
(
) These operations must be carried out by spe-
cialised personnel.
Disconnect the Anderson connector of the battery
wiring from the Anderson connector of the machine
wiring. Always hold the connectors with the hands
and never pull on the cables.
(
) Attach the battery wiring to the battery,
connecting the terminals only on the poles
marked with the same symbol (red wiring
"+", black wiring "-")! A battery short-circuit
may cause an explosion!
After checking that all the controls on the panel are
in position "0" or at rest, connect the battery con-
nector to the machine connector.
!
(
) Close the battery compartment making sure
not to crush any wires.
6.3 MACHINE PREPARATION
!
(
) Before starting to work, wear non-slip shoes,
gloves and any other personal protection device in-
dicated by the supplier of the detergent used or
considered necessary based on the operating envi-
ronment.
☞
(
) Do the following before starting to work. Refer
to the relative sections for a detailed description of
these steps:
check the battery charge level and charge, if ne-
cessary.
Mount the brushes or scraper disks (with the abra-
sive disks) that are suitable for the surface and
work involved.
Mount the squeegee, check that it is solidly atta-
ched and connected to the suction hose and that
the drying blades are not too worn.
Make sure that the recovery tank is empty. If not,
empty it completely.
Check and completely close the detergent solution
release control.
Fill the detergent solution tank with a mix of clean
29