6.0 OPTIONAL BLOWER INSTALLATION

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
BLOWER
Cut and remove the tie securing the blower switch wires
A.
to the heat shield.
Connect the white wire coming from below the appliance
B.
to the terminal on the blower.
Connect the black blower wire to the black wire coming
C.
from below the appliance.
Insert the clips on the blower housing into the cutouts in
D.
the rear shield. Push down to lock the clips into position.
Secure the blower using the screw and lock washer
E.
supplied.
NOTE: Ensure
that all the wires
are tucked into
the blower switch
housing.
SWITCHES
Open the switch housing by removing the top screw.
F.
Install the thermodisc bracket as shown, using 2 of the screws
G.
supplied. Connect the fl agged leads to the terminals of the
thermodisc.
Remove the knock out from the housing label.
Install the variable speed switch (rheostat) into the housing
H.
with the wires facing up. Secure the switch to the housing
using the pal nut and the knob supplied.
Connect the male connector on the switch to the female
I.
connector coming from the appliance.
Tuck all of the wires into the housing and close. Secure using
J.
the screw removed in step F.
!
RISK OF FIRE AND ELECTRICAL SHOCK.
VOID THE WARRANTY AND CERTIFICATION.
4
1
2
3
WARNING
7
4
5
7
29
7
9
8
4
4
1
2
3
7
9
8
W415-1332 / A / 11.21.14