EN
For natural gas connection;
Main Gas Pipe
Gasket
Nut
Natural Gas
Connection Hose
Gas hose passage way
Figure 1
Figure 2
WARNING: Before placint the appliance, check that the local distribution
conditions (gas type and pressure) conform to the product settings.
WARNING: Natural gas connection should
be done by authorized service.
For natural gas connection, place gasket
in the nut at the edge of natural gas connection
hose. To install the hose on main gas pipe,
turn the nut. Complete the connection by
making gas leakage control.
Connect the appliance to the gas piping
tap in shortest possible route and in
a way that ensure no gas leakage will
occur.
In order to carry on a tightness and
sealing safety check ensure that the
knobs on the control panel are closed
and the gas cylindir is open.
WARNING: While performing a gas
leakage check, never use any kind
of lighter, match, cigarette or similar
burning substance.
Apply soap bubble on the connection
points. If there is any kind of leakage
then it will cause bubbling.
While inserting the appliance in place
ensure that it is on the same level with
the worktop. If required adjust the
legs inorder the make level with the
worktop.
Use the appliance on a level surface
and in a well ventilated environment.