Operating Instructions
LCD Display Counters
E5024C Series
The E5024C Series display counters are battery-
powered. They are controlled by contact or voltage
pulses. They may be used in various applications, like
totalizing, parts counting, position acquisition, differential
Overview
Model
Operating mode Counting inputs
E5024C0400
Count
E5024C0408
E5024C0410
Cnt.Dir/Up.Dn
Table 1
DC models:
Count:
Fast and slow counting inputs
INP A: Fast counting input
INP B: Slow counting input
Cnt.Dir:
Counting and counting direction input
INP A: Counting input
INP B: Counting direction input
Up.Dn:
Differential counting input
INP A: Adding counting input
INP B: Subtracting counting input
MN05401007E
counting, etc. In addition, the various models with
specific input types may be extended using control
inputs to select operating modes.
INP A
4 – 30V DC
PNP
10 – 260V AC/DC
AC/DC 30 Hz
0 – 0.7V DC
NPN
AC/DC models:
Count:
Cnt.Dir:
Up.Dn:
INP B
12 kHz
0 – 0.7V DC
10 – 260V AC/DC
7 kHz
0 – 0.7V DC
Counting and reset inputs
INP A: AC/DC counting input
INP B: AC/DC reset input
Counting and counting direction input
INP A: AC/DC counting direction input
INP B: AC/DC counting input
Differential counting input
INP A: AC/DC subtracting counting input
INP B: AC/DC adding counting input
NPN
30 Hz
AC/DC
–
NPN
7 kHz
1