H - Configuring The Battery Charger - Wirbel SW1 450M ECO Utilisation Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 65
EN
10.1.h - Configuring the battery
charger (Fig. 23)
WARNING:
The machine leaves production with a
standard configuration for operation with
"Sonnenschein" gel batteries.
-
Remove the cover (1) by unscrewing the
screws (2).
Standard configuration with Sonnen-
schein gel batteries
-
Check that the jumper (3) is assembled
as shown in figure "D".
-
Remove the cap (4) located under the
batter charger (5).
-
Position the switches (DP1 and DP2) as
shown in figure "A".
It is possible to modify the configuration as
follows:
Configuration for gel batteries which are
not Sonnenschein version
-
Check that the jumper (3) is assembled
as shown in figure "D".
-
Remove the cap (4) located under the
battery charger (5).
-
Position the switches (DP1 and DP2) as
shown in figure "B".
Configuration for acid batteries
-
Remove the jumper (3) and position it as
shown in figure "E".
-
Remove the cap (4) located under the
battery charger (5).
-
Position the switches (DP1 and DP2) as
shown in figure "C".
2
2
2
3
D
EN-26
2
1
2
3
E
5
4
Fig. 23