• Art. 315: as this is a Class II device, the earth connection does
not have to be made. Connect Phase and Neutral on the two
free terminals that are indicated by the arrows.
• Art. 332: as this is a Class I device, the earth connection has
to be made. Connect Phase and Neutral on the two free termi-
nals that are indicated by the arrows; connect the earth on the
terminal that is indicated by the symbol
5.Connect the 5 screw anchors to the base using the screws pro-
vided, leaving some slack; place the 5 screw anchors in the holes
made previously (point 2), then press the base against the wall;
tighten the screw thoroughly.
6.Refit the body, making sure that the photoelectric cell wires do not
touch each other.
Detection sensitivity adjustment is made using the potentiometer
shown in the diagram, with higher sensitivity to the left and lower
to the right. If sensitivity is too high, the device will function continu-
ously in illuminated rooms. In all cases, the dryer must be attached
in such a way that the sensors are at least 50 cm from horizontal
surfaces in order to prevent infrared reflection.
During transport, one of the three sensors may come out of its seat
slightly. For the best dryer operation, the sensors must be well-seat-
ed (especially the middle one). If necessary, carry out this operation
carefully, making sure that the tangs of the LEDs do not come into
contact with each other. N.B. The blue sensors are infrared transmit-
ters and the white sensor is a receiver.
Use: Move your hands close to the appliance, it will automatically
activate. On moving away the appliance will automatically shut down
after a few seconds.