2.1 Stove setting
How to change the wished room temperature
Join the following procedure to change the wished temperature:
Press the key
(1) once to enter the menu and set temperature.
You will read the word "Set" and the wished temperature on the display.
Use the keys
(2) e
(3) to increase or reduce the wished value.
The stove will leave the menu Set temperature automatically as soon as you do not work
on it for some seconds.
How to change the working power
Join the following procedure to change the working power:
Press the key
(1) once to enter the menu and set the working power. You will read
the word "Pot" and the range of 5 possible powers on the display.
Use the keys
(2) and
(3) to increase or reduce the wished value.
The stove will leave the menu Set working power automatically as soon as you do not
use it for some seconds.
2.2 Remote control functions
Certain stove adjustment and check functions
are accessible solely via the multifunction remote
control.
TURBO function.
Press the TURBO key on the remote control to
enable the function. The display does not signal
the enabling of this function when the stove is off.
During the heating phase the stove goes to
maximum and the temperature set point goes to
30° for 30 minutes. At the end of the preset time
the stove resumes running at the set power and
temperature set point. During the heating phase
the stove signals this function by displaying "Turb"
alternated with other displays.
SLEEP function.
Press the SLEEP key on the remote control to
enable the function. The display does not signal
the enabling of this function when the stove is off.
After 60 minutes of heating, this function reduces
the temperature setting by 1°C to enable the stove
to use less energy. During the heating phase the
stove signals this function by displaying "Slee"
alternated with other displays.
AUTO function.
Press the AUTO key on the remote control to
enable the function. The display does not signal
the enabling of this function when the stove is off.
During the heating phase, the stove regulates the
heating power proportionally as the temperature
set point gets closer. During the heating phase
the stove signals this function by displaying "Auto"
alternated with other displays.
ECO function.
Press the ECO key on the remote control to
enable the function. The display does not signal
the enabling of this function when the stove is off.
During the heating phase the stove lowers the
heating power every 10 minutes until the minimum
is reached. During the heating phase the stove
signals this function by displaying "Eco" alternated
with other displays.
3.0 Turning on the stove
3.1 Suggestions
Do not continuously turn the stove on and off as this could provoke sparks that could
shorten the life of the electrical components.
Do not touch the stove with wet hands: the stove has electrical components that could
produce sparks if handled incorrectly. Only authorized technicians can resolve possible
problems.
ny screws from the fire chamber without first lubricating them well.
at the brazier basket is positioned correctly.
The flue system must be suitable for inspecion. If it cannot be removed, it must have
some holes for inspection and cleaning.
3.2 How to load pellets in the tank
You can load pellets in the tank through the door on the upper part of the stove.
Join the following procedure to load pellets:
Load the wished pellets quantity with caution (load enough pellets to grant a sufficient
r.
ATTENZIONE:
the furnace and ash drawer must be cleaned every day and prior to
each powering-on. Cleaning must consist in the complete removal
of all residue.
Failure to clean or incorrect cleaning may cause danger and harm.
Do not re-use the pellet possibly remained in the brazier due to no
starting-up.
3.3 Lighting
F
switch loca
The upper display will read
Press the button
for 2 seconds. After a few moments the smoke extractor and
the lighting resistor will start and the display will read "
is switched on.
After 1 minute the display will read
Once the appropriate temperature has been reached the display will read "
this means that the stove has begun the last phase in lighting, at the end of which the
stove will be completely opera
After several minutes of ventilation the display will read "O 1-2-3-4-5" and the room
temperature, according to the power tha
Once the programmed temperature is reached the display will read
room tempera
The temperature led lights when the programmed tempera
19
ation.
a
ACC.
the led resistence
LOAD PELL.
"
", the stove will load the pellets and
FIRE STAB.
switched off.
" and the
GB
":