Télécharger Imprimer la page

Orion ORLASER104 Manuel De L'utilisateur

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

ORLASER104 – Dual Scanner RG 
 
Multi‐Pattern Double Tunnel Red/Green Laser Effect 
Wide Dispersion Angle  
DMX, Audio Chase or Automatic Operation 
Integrated Microphone for Audio Chase 
Fan Cooled 
Includes Mounting Bracket 
 
General Information: 
Orion ORLASER104 Scanner laser is designed for indoor use only; the unit should never be exposed to 
rain or excess moisture.   Although properly vented and cooled, this laser effect should always be used 
in a ventilated space, away from external heat sources. 
Like all Class III A lasers, never look directly at the laser emitter as serious eye injury can occur.  Unit 
should never operate for more than two hours (continuous) without a brief cool down period to save 
heat stress damage to laser diodes.   
Do not insert anything into laser aperture as it may damage mirrors or cause motors to become 
misaligned.  Do not power up laser if aperture is obstructed in any way.   
The ORLASER104 should never be connected to any kind of external AC dimmer, and operate only at 
intended voltage.  There are no user serviceable parts inside.  Should the Scanner fail, it should be 
referred to qualified service technician for repair.  
ORLASER104 Front Panel 
1 – Laser Apertures 
2 – Microphone 
3 – Sound Active Indicator Light 
4 – Power Light 
 
 
 

Publicité

loading

Sommaire des Matières pour Orion ORLASER104

  • Page 1 ORLASER104 – Dual Scanner RG     Multi‐Pattern Double Tunnel Red/Green Laser Effect   Wide Dispersion Angle    DMX, Audio Chase or Automatic Operation   Integrated Microphone for Audio Chase   Fan Cooled   Includes Mounting Bracket    General Information:  Orion ORLASER104 Scanner laser is designed for indoor use only; the unit should never be exposed to  rain or excess moisture.   Although properly vented and cooled, this laser effect should always be used  in a ventilated space, away from external heat sources.  Like all Class III A lasers, never look directly at the laser emitter as serious eye injury can occur.  Unit  should never operate for more than two hours (continuous) without a brief cool down period to save  heat stress damage to laser diodes.    Do not insert anything into laser aperture as it may damage mirrors or cause motors to become  misaligned.  Do not power up laser if aperture is obstructed in any way.    The ORLASER104 should never be connected to any kind of external AC dimmer, and operate only at  intended voltage.  There are no user serviceable parts inside.  Should the Scanner fail, it should be  referred to qualified service technician for repair.     ORLASER104 Front Panel  1 – Laser Apertures  2 – Microphone  3 – Sound Active Indicator Light  4 – Power Light     ...
  • Page 2   ORLASER104 Back Panel  1 – AC Input   2 – Power Switch  3 – Cooling Fan  4 – Audio Sensitivity Knob   5 – DIP Switches  6 – DMX Signal Indicator  7 ‐ XLR DMX/Link Input / Output    Standalone Operation    Set dipswitches (see chart)  to either Sound Active or Auto Mode and power up unit.  After brief reset  the unit will begin to operate.  In Auto mode, the ORLASER104 will run randomly though its pattern  presets.  There is no laser off in auto mode.        In Sound Active mode, unit will respond to music at the microphone input and activate.  Set sensitivity  to ensure unit is active to music source only as desired.   The unit will step though its presets in response  to audio source and shut off when no music is present.     Master / Slave Operation    Up to 32 units can be linked to operate in unison without a controller.   Choose a master unit and set  dipswitch to either Auto or Sound Active mode.  Set subsequent units in ‘Slave’ mode and use standard  XLR cable to link.     DMX Operation    Set units to run in DMX (Slave) Mode and assign a channel using the DMX Quick Reference Chart  included in this manual.        ...
  • Page 3 DMX Operation Guide  Channel  Function  Value  Description  1  Mode  0‐49  Lasers Off  50‐99  Sound Active  100‐149  Auto Mode  150‐199  Static Patterns  200‐255  Dynamic Patterns  2  Pattern Select  0‐255  52 Static & Dynamic Patterns  3  Position X  0‐255  Adjust Laser on X‐Axis  4  Position Y  0‐255  Adjust Laser on Y‐Axis  5  Scanner Speed  0‐255  Set Scanner Speed (Slow (0) to –fast (255))  6  Pattern Speed  0‐255  Sets Speeds of Individual Patterns  7  Pattern Size  0‐255  Set Pattern Size (Small (0) to Large (255)) ...
  • Page 4: Informations Générales

    Double Tunnel Laser with over 100 Effects and Patterns   Input Power:      AC 100‐250V 50/60Hz  Power Consumption:    20 Watts  Dimensions (in):    12.2 x 7.2 x 3.4  Dimensions (mm):     310 x 185 x 86  Weight:        6.6 lbs / 3.0kg    ORLASER104 – Double Scanner RG     Effet Laser Double Tunnel À Multiples Motifs Rouge/Vert    Angle large de Dispersion   Fonctionnement en mode DMX, Audio Chase ou Automatique   Microphone intégré pour le mode activé par le son   Refroidissement Par Ventilateur   Inclut le support de fixation    Informations Générales:  Le Scanner Laser Orion ORLASER104 est conçu pour une utilisation intérieure seulement, l'unité ne doit  jamais être exposée à la pluie ou l'humidité excessive.   Bien que correctement ventilés et refroidis, cet  effet laser devrait toujours être utilisé dans un endroit aéré, loin de toute source de chaleur externe.  Comme pour tous les lasers Classe III A, ne jamais regarder directement l'émetteur laser. Cela pourrait ...
  • Page 5: Fonctionnement Autonome

      ORLASER104 Panneau Avant  1 – Ouverture du laser  2 – Microphone  3 – Indicateur Sound Active  4 – Indicateur D’alimentation        ORLASER104 Panneau Arrière  1 – Entrée CA   2 – Interrupteur d'alimentation  3 – Ventilateur de refroidissement  4 – Bouton de sensibilité audio  5 – Commutateurs DIP   6 – Indicateurs de signal DMX   7 ‐ XLR DMX/Link Entrée / Sortie    Fonctionnement autonome    Réglez les commutateurs DIP (voir le graphique) à la position de Mode Sound Active ou Auto et  procédez à la mise sous tension et l’appareil.  Après une brève réinitialisation, l’appareil se mettra en  marche.  En mode Auto, le ORLASER104 passera au hasard à travers les préréglages de motifs.   Le laser  n’est jamais éteint en mode auto.        En mode Sound Active, l’appareil répondra au son de la musique à l’entrée pour microphone et  s’activera.  Régler la sensibilité de l’appareil pour vous assurer qu’il s’activera seulement à la source de  musique tel que désiré.  L’appareil passera à travers sa gamme de préréglages en réponse à la source  audio et passera à l’arrêt quand aucune musique n’est présente.    ...
  • Page 6 Opération Maître / Esclave     Jusqu'à 32 unités peuvent être liées pour fonctionner à l'unisson sans contrôleur.  Choisissez une unité  maître et réglez le commutateur DIP soit en mode Auto ou Sound Active. Réglez les unités subséquentes  en mode esclave et utilisez un câble XLR pour les raccorder.     Opération DMX     Réglez les unités pour qu’elles fonctionnent en mode DMX (esclave)  et assigné un canal en utilisant le  tableau de référence DMX contenu dans ce manuel.           Guide d’Utilisation DMX   Canal  Fonction  Valeur  Description  1  Mode  0‐49  Lasers Off  50‐99  Sound Active  100‐149  Mode Auto   150‐199  Motifs Statiques  200‐255  Motifs Dynamiques  2  Sélection de motifs  0‐255  52 Motifs Statiques et Dynamiques   3  Position X  0‐255  Ajuste le Laser sur l’axe X  4  Position Y ...
  • Page 7 Tableau de référence rapide pour adresse DMX      Spécifications  Sortie laser:      150mW@650nm Rouge, 40mW@532nm DPSS Vert  Modes de fonctionnement:  DMX, activé par le son, Automatique  Contrôle DMX      7 Canaux  Graphiques Et Effets    Laser Double Tunnel avec plus de 100 effets et motifs  Puissance d’entrée:    CA 100‐250V 50/60Hz  Consommation de puissance:  20 Watts  Dimensions (po):    12.2 x 7.2 x 3.4  Dimensions (mm):     310 x 185 x 86  Poids:        6.6 livres / 3.0kg   ...