Starting

1. Start the engine of the vehicle with the drained battery
(starting attempt max. 15 seconds - wait at least one minute between
additional attempts to start).
2. after successfully starting the vehicle engine with the drained battery
wait 2 to 3 minutes until it runs smoothly.

Disconnecting

Note: before disconnecting the jumper leads the rear and front defrost should be
switched on in the vehicle with the drained battery (do not switch on vehicle lights).
this will reduce possible voltage spikes whilst disconnecting and prevent damaging
electrical parts. Disconnect the terminal clamps in the following order:
Caution!
when disconnecting the jumper cables, be careful they do not come into contact
with the moving parts of the engine.
1. Negative lead (black) from earth point of vehicle with drained battery.
2. Negative lead (black) from negative terminal of good battery.
3. Positive leads (red) in any order.
after jumpstarting drive the broken-down vehicle for a longer distance to charge the
battery. you may also recharge the battery with a charger.