Connecting the Appliance
1. Attach the air inlet hose to the flue manifold on
either inlet position "a" or "b".
The plastic tie should be tight over the sleeve.
The unused inlet is plugged with the rubber cap
supplied on the manifold.
2. Connect the flue elbow to the manifold while
moving the appliance into position.
3. Fit the pipe stopper over the connection between
the flue elbow and the manifold. Engage the
hook and rotate it until it snaps against the body
of the clamp.
4. Slide the insulation sleeve up to the flue manifold
and slip the securing clip over the sleeve as
shown.
5. Install the bracket on the rear of the top spacer by
tightening 2 screws.
6. Install the wall bracket with two screws. Install
the top spacer by clipping the spacer into the wall
brackets and attaching it to the heater with 2
screws.
Spacer
Top Spacer
Bracket
26
Wall
Bracket
Rinnai Corporation EX08C, EX11C Manual
a
Flue Manifold
Pipe stopper
Manifold
Elbow
2 screws
b
Hook
Pipe stopper
Fit Clip
Slide
Sock
Top Spacer
Spacer
Bracket
Wall
Bracket