Drilling Flue Hole

Ensure that there are no gas or water lines, or
electrical circuits in the wall location where the flue hole
is to be drilled. Drill the flue hole using a 3 1/8 inch (80
mm) drill. The center of the hole must be located
exactly at the specified point.
See diagram. For weatherboard walls, drill through the
center of the weatherboard from the outside first and
then through the plasterboard. A template is provided.
For installation without using extension kits, the
configuration of the flue manifold, air intake hose, and
exhaust slide pipe should be as shown when
installation is completed. The 60 degree arc shows
where the flue manifold can be located.

Dimensions

A full size template is provided on the
NOTICE
cardboard packaging.
DO NOT DISCARD until installation is
completed.
Flue Hole
NOTICE
• •
Rinnai Corporation EX08C, EX11C Manual
Use a template (included) to
determine allowable location of the
flue hole.
10.1 in
257 mm
6.8 in
3.3 in
172 mm
85
17