Food Safety; Use And Care - Char-Broil 14101480 Guide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Food Safety

Food safety is a very important part of enjoying the
outdoor cooking experience. To keep food safe from
harmful bacteria, follow these four basic steps:
Clean: Wash hands, utensils, and surfaces with hot
soapy water before and after handling raw meat and
poultry.
Separate: Separate raw meats and poultry from ready-
to-eat foods to avoid cross contamination. Use a clean
platter and utensils when removing cooked foods.
Cook: Cook meat and poultry thoroughly to kill bacteria.
Use a thermometer to ensure proper internal food
temperatures.
Chill: Refrigerate prepared foods and leftovers promptly.
For more information call: USDA Meat and Poultry
Hotline at 1-800-535-4555 In Washington, DC (202)
720-3333, 10:00 am-4:00 pm EST.
How To Tell If Meat Is Cooked Thoroughly
• Meat and poultry cooked in the appliance often
browns very fast on the outside. Use only thawed
meat and a meat thermometer to be sure food has
reached a safe internal temperature, and cut into food
to check for visual signs of doneness.
• We recommend food to be at least 40°F before
cooking in your appliance.
• Whole poultry should reach 165° F. Juices should run
clear and flesh should not be pink.
• Beef, veal and lamb steaks, roasts and pork chops
can be cooked to 145° F.
• NEVER partially cook meat or poultry and finish
cooking later. Cook food completely to destroy harmful
bacteria.
• Use a meat thermometer to ensure proper internal
food temperatures.
USDA Recommended
Internal Cooking Temperatures
Ground Meat
Beef, Pork, Veal, Lamb......................................160°F
Turkey, Chicken.................................................165°F
Fresh Beef, Veal, Lamb
Medium Rare.......................................................145°F
(let stand 3 minutes before cutting)
Medium................................................................160°F
Well Done............................................................170°F
Poultry
Chicken & Turkey, whole.....................................165°F
Poultry Parts.......................................................165°F
Duck & Goose....................................................165°F
Fresh Pork
Medium Rare......................................................145°F
(let stand 3 minutes before cutting)
Medium..............................................................160°F
Well Done..........................................................170°F
Storing Your Appliance
• Clean cooking basket.
• Store in dry location.
• When LP cylinder is connected to appliance, store
outdoors in a well-ventilated space and out of reach of
children.
• If the regulator is disconnected from the LP cylinder, a
hook is provided to hang the regulator from the handle
as shown.
• Cover appliance if stored outdoors. Choose from a
variety of covers offered by the manufacturer.
• Store indoors ONLY if LP cylinder is turned off and is
disconnected, removed from appliance and stored
outdoors.
• When removing appliance from storage, follow
"Cleaning the Burner Assembly" instructions before
starting.

USE AND CARE

DANGER
• NEVER store a spare LP cylinder under or near
the appliance or in an enclosed area.
• Never fill a cylinder beyond 80% full.
• An over filled or improperly stored cylinder is a
hazard due to possible gas release from the
safety relief valve. This could cause an intense
fire with risk of property damage, serious injury
or death.
• If you see, smell or hear gas escaping,
immediately get away from the LP
cylinder/appliance and call your fire department.
• Keep LP tank at a minimum distance of 24"
(inches) away from appliance at all times.
24"
LP Cylinder Removal, Transport and Storage
•Turn OFF all control knobs and LP cylinder valve. Turn
coupling nut counterclockwise by hand only - do not use
tools to disconnect. Loosen cylinder screw beneath
bottom shelf or disconnect other retention means, then lift
LP cylinder up and and out of cart. Install safety cap onto
LP cylinder valve. Always use cap and strap supplied
with valve. Failure to use safety cap as directed may
result in serious personal injury and/or property
damage.
3
•A disconnected LP cylinder in storage or being
transported must have a safety cap installed (as
shown). Do not store an LP cylinder in enclosed
spaces such as a carport, garage, porch, covered patio
or other building. Never leave an LP cylinder inside a
vehicle which may become overheated by the sun.
•Do not store an LP cylinder in an area where children play.
LP Cylinder Valve
Regulator Hook
LP (Liquefied Petroleum Gas)
•LP gas is nontoxic, odorless and colorless when
produced. For Your Safety, LP gas has been given an
odor (similar to rotten cabbage) so that it can be smelled.
•LP gas is highly flammable and may ignite unexpectedly
when mixed with air.
LP Cylinder
•The LP cylinder used with your grill must meet
the following requirements:
•Use LP cylinders only with these required
measurements: 12" (30.5cm) (diameter) x 18" (45.7
cm) (tall) with 20 lb. (9 kg.) capacity maximum.
•LP cylinders must be constructed and marked in
accordance with specifications for LP cylinders of the
U.S. Department of Transportation (DOT) or for Canada,
CAN/CSA-B339, cylinders, spheres and tubes for
transportation of dangerous goods, Transport Canada
(TC). See LP cylinder collar for marking.
•LP cylinder valve must have:
•Type 1 outlet compatible with
regulator or grill.
•Safety relief valve.
•UL listed Overfill Protection Device (OPD). This OPD
safety feature is identified by a unique triangular hand
wheel. Use only LP cylinders equipped with this
type of valve.
•LP cylinder must be arranged for vapor withdrawal
and include collar to protect LP cylinder valve.
Always keep LP cylinders in upright position
during use, transit or storage.
LP Cylinder Filling
•Use only licensed and experienced dealers.
•LP dealer must purge new cylinder before filling.
•Dealer should NEVER fill LP cylinder more than 80% of
LP cylinder volume. Volume of propane in cylinder will
vary by temperature.
•A frosty regulator indicates gas overfill. Immediately close
LP cylinder valve and call local LP gas dealer for
assistance.
•Do not release liquid propane (LP) gas into the
atmosphere. This is a hazardous practice.
•To remove gas from LP cylinder, contact an LP dealer or
call a local fire department for assistance. Check the
telephone directory under "Gas Companies" for nearest
certified LP dealers.
Safety Cap
Retainer Strap
OPD Hand Wheel
LP cylinder in upright position for
vapor withdrawal

Publicité

Table des Matières
loading

Table des Matières