Y910 Intrinsically Safe Pressure Transmitter
Measurement of vacuum, absolute or gauge pressure
TRANSBAR
ceramic technology
®
Zero adjustment as standard (±10% of range)
Welded construction – reinforced product
Modularity of electrical and hydraulic connections
Highly resistant to severe process conditions (≥ 10
pressure cycles)
Marine version (Bureau Veritas Marine)
LCIE 02 ATEX 6133X
CE
0081
I M1 G and D
EEx ia I
II 1 G and D
EEx ia IIC T6 or T5
Hazardous area: 0, 1, 2, 20, 21, 22
The Y910 pressure transmitters allows pressure measurements on most cor-
rosive fluids, in hazardous areas.
Technical data (20°C)
Measurement range
From 0...25 mbar to 0...600 bar
Compound, gauge or absolute pressure
Output signal
Y912 : 0...10 Vdc.
(except -1...0 bar where -1 = 20 mA, 0 = 4 mA)
Y914 : 1...5 Vdc.
Supply voltage
Y912 : 14...28 Vdc
Y913-Y914 : 11...28 Vdc
Y916 : 8...28 Vdc
Option
Low voltage : 8...28 Vdc (Y913, Y914)
Power supply electrical parameters device must
be: U
See drawings overleaf for more details.
Insulation
> 100 MΩ at 500 Vdc
Maximum input current
Y912-Y914 : 6 mA
Y916 : < 25 mA
Y912 : ≥ 2.5 k Ω
Load impedance (+M / –M)
Y913 : R
Y913 : R
Y916 : R
CE Conformity
CEM Directive 89/336/CE with screened cable,
screen connected at both ends.
Pressure Directive 97/23/CE.
ATEX Directive 94/9/CE .
Global error (linearity, hysteresis and repeatability) by reference to BFSL
Typically: ±0.2% of F.S. / Max.: ±0.3% of F.S.
For P ≤ 60 mbar and P= 600 bar:
Typically: ±0.6% of F.S. / Max.: ±1% of F.S.
www.baumerprocess.com
Modifications reserved
Y913 : 4...20 mA
Y916 : 0...20 mA
≤ 28 Vdc ; I ≤ 120 mA ; P ≤ 0.8 W
supply
≤ (U
= 200 Ω
-11)/0.02 ; R
Ω
supply
c min
≤ (U
-8)/0.02 (low voltage option)
Ω
supply
≤ (U
= 100 Ω
-6)/0.02 ; R
Ω
supply
c min
7
Operating temperature
Ambient (Ta)
Ta = +40°C
Ta = +70°C
Fluid
Storage temperature
Compensated temperature range (zero and sensitivity)
Zero thermal drift
Span thermal drift
Wetted parts
Standard connections
Protection rating (EN 60529)
Typical response time
Vibration resistance (IEC 68-2-6) 1.5 mm (10-55 Hz), 20 g (55 Hz to 2 kHz)
Shock resistance (IEC 68-2-32) 25 falls from 1 m on concrete ground
-25...+70°C
G : T6
D IP65 : T°surface = +80°C
G : T5
D IP65 : T°surface = +95°C
(G = Gas ; D = Dust)
-25...+100°C (Ta ≤ 50°C) depending on class
-40...+85°C
-10...+55°C. Option: -10...+70°C
±0.025% F.S./°C max. (except P ≤ 1 bar : ±0.06% F.S./°C)
Option : ±0.015% F.S./°C max. (except P ≤ 1 bar : ±0.025% F.S./°C)
Typically: ±0.01%/°C / Max.: ±0.015%/°C
Ceramic + stainless steel 1.4404 (316L) + NBR
seal (standard) for ranges ≥ 250 mbar and Viton
for ranges < 250 mbar
Electrical : DIN 43650 connector
Pressure : G1/2
Many options available
Standard : IP65 (DIN connector)
Option : IP67 or IP68 (depending on connection)
≤ 3 ms
Data sheet A11.11
®
Page 1