Installation and connection
NOTE
Excessive water pressure in the system will damage the unit.
Ensure that the distance from the highest water withdrawal point does not exceed 15 m.
Ensure that the system pressure does not exceed 10 bar.
Adhere to the maximum permissible pump pressure. It may be less than 10 bar.
A
The unit can be connected horizontally or vertically at any point between the pressure connec-
tion of a garden pump, deep well pump or submersible pressure pump and the first water with-
drawal point (e.g. washing machine).
• Recommendation: Fit directly to the pressure connection of the pump. Use an adapter.
How to proceed:
B
1. Screw the adapter onto the pump.
– Ensure that the O-ring is correctly seated.
2. Screw the unit onto the adapter.
– When fitting, ensure that the arrow on the cover and the outlet of the unit point in the di-
rection of the water flow.
3. Connect the unit to the downstream line.
NOTE
Ensure that all connection lines are completely leak-tight, as leaking lines can impair the function
of the system and lead to damage.
Use a suitable sealant to seal the threads of the lines and the connection to the pump.
Overtightening of plastic screw connections can lead to damage. Do not apply excessive force.