Télécharger Imprimer la page

Miele FRZ01 Notice De Montage page 30

Masquer les pouces Voir aussi pour FRZ01:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
Produktgruppe 512
30 von 32
Note
This installation kit, mat. no. 06256860, contains:
1 flow meter
1 water intake adapter
3
2
/
-inch gaskets, 16 x 23.8 x 1.5
4
Assorted cable ties, 98 x 2.5
1 cable fitting, M 12 x 1.5
1 wiring diagram for MF07 PW impeller module
1 wiring diagram for PW 6107 6207 module 7
These installation instructions, mat. no. 06258812.
List of figures:
Fig. 1, flow meter connection to
shutoff valve
Fig. 2, Connecting the flow meter to a water intake hose or Y-piece
Note
PW 6107, PW 6137, PW 6167, PW 6207
Before installing the flow meter, make sure that the MF07 10 20 PWxx7 multifunction module is already installed in the machine.
Register the MF07 module.
Service Settings Register module EZL with code 7 Register module? OK Diskette symbol
Note
PW 6101, PW 6131, PW 6161, PW 6201
Before installing the flow meter, make sure that the MF07 PW impeller module is already installed in the machine.
Register the MF07 module.
Service Settings Register module MFM with code 7 Diskette symbol (to save the registration). Or: Service Settings
Register module EZL with code 7 Register module? OK Diskette symbol
Note
PW 6163, PW 6243, PW 6323
Before installing the flow meter, make sure that the BSF-RU impeller module is already installed in the machine.
Note
During installation, the adapter must be used as a straight-pipe length between the shutoff valve and the flow meter. Observe the arrow
marking on the flow meter indication the correct direction of flow. Use only a sealing compound appropriate for the pipe diameter, so that
the water will flow without any additional turbulence. Only by observing these instructions can the flow meter provide the correct values.
Disconnect the machine from the electrical supply and the gas supply (if required) and secure against resetting.
Connect the flow meter to a
Connect the flow meter to a water intake hose or Y-piece. See Fig. 2.
Note
PW 6107, PW 6137, PW 6167, PW 6207
Remove the screws securing the machine lid.
Tilt the lid slightly forwards, push it back and release it.
Remove the machine lid.
Knock out the pre-punched hole on the rear panel.
Install the cable guide on the rear panel
Electrically connect the flow meter in accordance with the PW 6107 6207 module 7 wiring diagram.
Re-install the machine lid.
15.08.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
3
/
4
3
/
-inch shutoff valve. See Fig. 1 .
4
Umbau- und Montageanweisung
M.-Nr. 06258812

Publicité

loading