T echnical features
Slow-down (soft stop)
At stroke end the unit reduces the speed of leaves (Soft stop function) so to avoid strong impacts.
Power supply
The power to electronic card and motors is supplied by an electric transformer equipped with protection fuse. It is possible to connect to the
equipment an optional battery to guarantee the working of the automation when electric power is missing.
Radio receiver
The electronic card CTR500 contains a 2 channels radio receiver. The receiver can memorize up to 100 codes. The channel 1 of receiver acts as
Start, while the channel 2 acts as Pedestrian Start.
Extra-push (DP4=ON)
It is possible to enable the "extra-push" function, used to make easy the release of electric lock in bad weather conditions. The "extra-push"
function operates only with closed gate and is a logical sequence starting the electric lock during a short closing step (1 sec. approx.) and disables
it only after the leaf's start in opening. At closing end the electronic card supplies a short acceleration on both leaves (1,5 sec) at the maximum
speed so to make easy the electric lock's insertion.
Erase of all delays (DP5=ON)
This function allows you to cancel all the delays between the leaves. The two leaves open and close simultaneously.
Working logic
"Step-by-Step" logic (Dip 1 = OFF Dip 2 = ON)
A Start control puts into motion, a following control stops the motion, a further Start control reverses the motion (direction reverse).
"Automatic closing" (Dip 1 = ON Dip 2 = ON)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied during the pause interrupts work
cycle and the gate doesn't close automatically. Photocell intervention during pause time reloads it, extending the period before automatic closing.
"Condominium" logic (Dip 1 = irrelevant Dip 2 = OFF Dip 3 = irrelevant)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied while opening is irrelevant. A Start
control supplied while closing provokes the stop and gear reverse after approx. 1,5 sec.. A Start control or Photocell intervention during pause
time reloads it, extending the period before automatic closing. .
WARNING: after each modification of the working logic, switch the control unit off and on again to make the change active.
"Immediate closing" (DP3=ON
DP2=ON)
In opening phase and during pause time, after having passed the Photocell, it determines the stop and, after 1,5 sec., gate closing.
Electric power lack
Following to a temporary electric power lack, at recovery the first Start control determines an opening cycle.
"Single leaf" operation
In single leaf operation, the operating logics described above remain unchanged.
In case of single leaf gate, set DP5=ON and connect the leaf to the motor M2.
Programming
Learning of remote controls
To enter a START code, press the P1 key once. To enter a PEDESTRIAN START code, press the P1 key twice. Each time the P1 key is pressed, the
DL1 led emits a short flash. After 3 seconds from the last pressure of P1, the DL1 led turns on with a steady light. Then press the key to be
memorized on the remote control. The DL1 led will switch off, indicating that the code has been memorized. If the code is not recognized, the DL1 led
stays on for 10 sec., after which it will automatically switch off.
Erasing of all memorized codes
To delete all the stored codes, keep the P1 key pressed for approx. 10 sec. until the DL1 led turns off.
Setting of pause time and the M2 motor's closing delay
the M2 motor's closing delay,
To set the pause time, press the P2 key once. To set
press the P2 key twice. Each time the P2 key is pressed, the DL1
led emits a short flash. After 3 seconds from the last pressure of P2, the DL1 led turns on with a steady light. Let pass the time corresponding to the
desired time and press again the key P2.
Programming of work time for M1 leaf
Rotate the RV1 trimmer to the maximum clockwise. Make sure the leaf M1 is completely closed. Press button P3 for about 3 sec., DL1 led will
turn on with steady light. Press the P1 key to open the M1 leaf with reduced speed. At the end of opening the M1 motor stops and the leaf starts
to close with the maximum speed. At the end of closing the leaf stops automatically.
Programming of work time for M2 leaf
Rotate the RV1 trimmer to the maximum clockwise. Make sure the leaf M2 is completely closed. Press button P3 for about 3 sec., DL1 led will
turn on with steady light. Press the P2 key to open the M2 leaf with reduced speed. At the end of opening the M2 motor stops and the leaf starts
to close with the maximum speed. At the end of closing the leaf stops automatically.
Warning: it is obligatory to install the mechanical stops on opening and closing
Electrical and mechanical features
Dimensions and Weight of card: 170 x 90 x 46 mm - 0,26 Kg
Main power supply: 230 Vac +/- 10%
Stand-by power consumption: 1 W approx.
Working temperature: from 0 to + 60 °C
Single motor maximum power: 40 W (CTR500) / 60 W (CTR500/PW) / 80 W (CTR500/STR)
Blinker power supply: 12 Vdc - 5 W max
Open gate lamp power supply: 12 Vdc - 1 W max
Electric lock power supply: 12 Vac 15 W max
Accessory power supply: 12 Vdc 3 W max
Battery charger capacity: 0,1 A
Relay contact capacity: 30 A
Amperometric Stop regulation: from 50 to 87%
Programming of motor work time: 120 seconds max
Programming of delay in closing M2: 60 seconds max
Programming of pause time: 300 seconds max
Operating frequency: 433,92 or 868,35 MHz
DECLARATION OF CONFORMITY
Unit description: Universal electronic board controlling 1 or 2 motors operating at 12/24 Vdc destined to the gate automation
Model: CTR500
Applied rules: EN 61000-6-3, EN 61000-6-1, EN 301489-1, EN 301489-3, EN 300220-2, EN 300220-1, EN 60950-1
Test laboratory : NEMKO SPA
Outcome: Positive
The manufacturer declares that the above listed products comply to the norms provided for by European directives 2004/108/EC and 2006/95/EC.
Date: 22-06-2020