Troubleshooting - Panasonic CS-Z20TKEW Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16

Troubleshooting

The following symptoms do not indicate malfunction.
Symptom
Mist emerges from indoor unit.
Water fl owing sound during operation.
The room has a peculiar odour.
Indoor fan stops occasionally during automatic
fan speed setting.
Airfl ow continues even after operation has
stopped.
Operation is delayed a few minutes after
restarting.
Outdoor unit emits water/steam.
TIMER indicator is always on.
POWER indicator blinks during HEAT mode
with no warm air supply (and fl ap is closed).
Indoor fan stops occasionally during heating
operation.
POWER indicator blinks before the unit is
switched on.
Cracking sound during operation.
Splashing sound during operation.
Dusts accumulated on the wall.
During COOL/DRY mode, the indoor unit
stops and POWER indicator blinks.
Discoloration of some plastic parts.
Check the following before calling for servicing.
Symptom
Operation in HEAT/COOL mode is not working
effi ciently.
Noisy during operation.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.
The unit does not receive the signal from the
remote control.
• Condensation effect due to cooling process.
• Refrigerant fl ow inside the unit.
• This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
• This helps to remove the surrounding odour.
• Extraction of remaining heat from the indoor unit
(maximum 30 seconds).
• The delay is a protection to the unit's compressor.
• Condensation or evaporation occurs on pipes.
• The timer setting repeats daily once set.
• The unit is in defrost mode (and AIR SWING is set to
AUTO).
• To avoid unintended cooling effect.
• This is a preliminary step in preparation for the
operation when the ON timer has been set.
When ON Timer is set, the unit may start earlier (up
to 35 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Changes of temperature caused the expansion/
contraction of the unit.
• Generating the nanoe on the unit.
• Due to air circulation or static electricity generated
by the air conditioner. Some types of wall paper may
collect dusts easily (recommended to clean the area
around the air conditioner frequently).
• The system has locked to operate in HEAT model only.
• Discoloration is subject to material types used in plastic
parts, accelerated when exposed to heat, sun light, UV
light or environmental factor.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet
vents.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
• Insert the batteries correctly.
• Replace weak batteries.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
• Make sure the receiver is not obstructed.
• Certain fl uorescent lights may interfere with signal
transmitter. Please consult authorised dealer.
Cause
Check
13

Publicité

Table des Matières
loading

Table des Matières