14
installation instructions
• The safety during use can only be guaranteed when the oven is installed correctly and according to the regulations. The installer is
responsible for any damage caused by a faulty installation.
• The electrical connection must be made by a qualified electricien. This person is aware of the national and local regulations the
installation must comply with.
• The appliance falls under protection class I and can only be used in combination with a grounding conductor connection. The
manufacturer accepts no responsibility for any malfunction or damage caused by incorrect electrical installations.
•
The appliance must be connected to a fixed installation and the means of disconnecting it from the fixed installation must be
installed according to the installation instructions.
• The connection cable must hang freely. Do not tie the power cable or pass it along sharp edges. It must be positioned so that it
does not touch any of the hot parts of the oven.
• The connection point, the wall socket and/or plug must always be accessible.
• The cabinet into which the oven is fitted, must be heat resistant (> 90°C). This includes cabinet doors and fronts.
• Ensure that the cabinet into which the oven is installed is secure. For example, by mounting it to the adjoining elements.
• Damage caused by incorrect connection, incorrect use or incorrect fitting is not covered by the guarantee.
Attention: any change to the appliance's interior, including fitting and changing the power cable, must only be performed by a
qualified electricien.
INSTALLATION DIMENSIONS
In the drawings below, all the dimensions are displayed in mm.
min. 560+8
min.
550
Ventilation grid
30
•
English
560
19 (*20)
454
595
565
min. 45
Cupboard feet
min. 560+8
560
565
19 (*20)
454
595