Start the circulator pump alone (without starting the heating element) until the air is eliminated from the water circuit:
1.
For the version without control box, set the regulation thermostat (see page 10) on the 0°C position and then plug the power cable to the network.
You can regulate the thermostat to 15°C when you are sure that no air is inside the circuit anymore. The thermostat is now regulating the heating
element.
2.
For the version with control box, set the switch on the « off » position and plug the power cable to the network (« GREEN » lamp is on). You can set
the switch on the "on" position when you are sure that no air is inside the circuit anymore. The thermostat is now regulating the heating element.
For the version with digital control box, switch off the circuit breaker inside the control box and plug the power cable to the network ("GREEN" lamp is
3.
on). You can switch on the magneto-thermic circuit breaker when you are sure that no air is inside the circuit anymore. The thermostat is now
regulating the heating element.
Water circuit diagram (example)
1. Aqualine
2. Filter
3. Air bleed valve
4. Anti return valve
5. Over pressure valve
6. Isolation
7. Drinking bowl
3.4. Electrical connections
Connect to a 230 VAC single-phase circuit.
Use a 30 mA differential circuit breaker and ground according to the rules in force (MANDATORY)