Technical instructions

3.3. Installation into a CCEI wall inlet

If you prefer to install a Mini Brio 2 into a CCEI wall inlet (see next images), you have to place the O-ring inside the wall inlet
(use some grease during the installation). Once compressed during tightening, the O-ring allows a dry sheath between the back
of the light and the connection box above the water level.
This allows to increase the watertighness of the connection box and limit frost risk in sheath. This O-ring will not guarantee
the watertightness of the installation. It will improve the protection of the connection box. If the light is not well screwed and
under the water level, the sheath will be filled directly with water.
One-piece or concrete pool (PF10R291)
Liner pool (PF10R292)

4. Dimming / luminous intensity variation (Only PK10R311-312)

You have the possibility to manage the luminous intensity of your lights with micro-power cuts (<1s). 3 levels are available :
• 1 micro-cut = 100% of power
• 2 micro-cuts = 75% of power
• 3 micro-cuts = 50% of power
• 1 micro-cut = Back to 100%
Mini Brio 2 M12 & X12
A. Set the O-ring in the wall inlet and pass the cable
B. Push and screw the light
C. Use the supplied tool to screw the light thoroughly
A. Set the O-ring in the wall inlet and pass the cable
B. Push and screw the light
C. Use the supplied tool to screw the light thoroughly
D. Clip the supplied flange on the wall inlet
v1.0ML