ENGLISH
TECHNICAL DATA
Power supply:
Electrical input:
Adjustment range: Pump:
Valve:
Temperature indication:
Accuracy:
Resolution:
Hysteresis:
Alarm temperature:
Anti-freeze temperature:
Sensor type (outside):
Contact rating:
Protection rating:
Type of action:
Pollution degree:
Overvoltage category:
Class of protection against
electric shock:
Rated inpulse voltage:
Tracking Index (PTI):
Number of manual cycles:
Number of automatic cycles: 50.000
Software class:
EMC test voltage:
EMC test current:
Distances tolerances fault
mode 'short' exclusion:
Ball pressure test temperature: 75°C
Operating temperature :
Storage temperature:
Humidity limits:
Enclosure:
material:
colour:
Dimensions:
Weight:
CLASSIFICATION UNDER REG. 2013.811.EC
Class:
Contribution to energy efficiency:
OVERVIEW
The FUEGO 2 control unit (Fig. 1) is specifically
designed for applications in hydronic fireplaces, which
can be used to heat water that is then delivered both
to the traditional home heating system by means of a
pump and to a boiler by means of a valve.
The unit is equipped with two dials: one for adjusting
the pump temperature and the other one for the valve
temperature.
The controller relies on a sensor to measure the
temperature of the water inside the boiler of the
fireplace: when the temperature exceeds the setpoint
selected by means of the dials, the proper relevant unit
is switched on (pump, valve, or both).
230V~ ±10% 50/60Hz
1.5VA
30°C .. 90°C
50°C .. 70°C
30°C .. 90°C
± 3°C
5°C
3°C asymmetric
90°C ± 1,5°C
5°C ± 1°C
NTC 4.7kΩ @ 25°C
code STL NTS A150
5A @ 250V~ (cosφ=1)
SPST (N.A.)
IP 20
1
2
II
II
2500V
175
50.000
n.a.
230V~
14mA
±0,15mm
0°C .. 40°C
-10°C .. +50°C
20% .. 80% RH
(non-condensing)
ABS self-extinguishing V0
Anthracite grey
(RAL 7016)
118x61x55 mm (LxAxP)
~ 400 gr.
I
1%
A scale of seven luminous indicators (LEDs) enables a
reading of the water temperature: the last two are red
and signal a condition where the water is excessively
overheated.
The last one in particular lights up at 90°C and is also
associated with an audible alarm signal that alerts the
user to immediately reduce the quantity of heat
produced by the fireplace. For safety reasons the
audible alarm is activated even if the controller is
switched OFF.
In addition to its normal functions, FUEGO 2 also
features a specific on/off switch for activating an
additional output typically used for the GRILL motor,
which can work only if the controller is switched ON.
When the temperature falls below 5°C, the controller
activates the antifreeze function of the circulation
pump.
This function is available only if the controller is not
switched OFF.
INSTALLATION
FUEGO is designed to be installed in conjunction with
standard recess mount boxes consisting of three type
503E modules.
Depending on the type of cover plate used the plastic
housing must be adapted as follows (see Fig. 3).
Use of AVE SISTEMA 45
No change required.
Use
of
BTICINO
®
International
).
Remove the tabs 'A', cutting them along the line (1).
®
Use of VIMAR IDEA
Remove the tabs 'A', cutting them along the line (2).
®
AVE SISTEMA 45
, BTICINO LIVING
®
IDEA
are trademarks registered by the legitimate
owners.
The product is supplied complete with a trap suitable
for installation on the outlet pipe and a temperature
sensor with a 150 cm long cable and 6 x 25 mm tube.
a
WARNING
- Avoid pairing the cables of the remote sensor
with the power lines. Use a bipolar shielded cable
with a minimum cross-section size of 1.5 mm2
(excluding the braid) and max. length of 25 m.
- The appliance must be wired to the electric mains
through a switch capable of disconnecting all
poles in compliance with the current safety
standards and with a contact separation of at
least 3 mm in all poles.
- Installation
and
appliance must be made by qualified technicians
and in compliance with the current standards.
- Before wiring the appliance be sure to turn the
mains power off.
In the view of a constant development of their products, the manufacturer
reserves the right for changing technical data and features without prior notice.
The consumer is guaranteed against any lack of conformity according to the
European Directive 1999/44/EC as well as to the manufacturer's document
about the warranty policy. The full text of warranty is available on request from
the seller.
3
®
cover plate
LIVING
cover
plate
cover plate
®
and VIMAR
electrical
wirings
(not
of
this