Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7.3 - ERRORS

In case of a problem, the device shuts down and the display will show one error message from the following list.
Message
Description
Battery power
(The
E1
decreased below the set threshold.)
Power overload from the cooling fan
E2
(The cooling fan overloads the board beyond
the allowed limit. Possible cause: short circuit or
something is blocking the fan from rotating.)
Blocked compressor
(The rotor is blocked or the pressure in the
E3
cooling circuit is too high.)
Minimum compressor rotation speed
(If the cooling circuit is overloaded, the
E4
compressor is unable to maintain minimum
rotation speed.)
High temperature in the control board
(If the cooling circuit is overloaded or if the
E5
surrounding temperature is too high, the control
board signals this issue.)
Communication error
E6
(No communication between the display and the
control board.)
Temperature probe
E7
(If the probe has short circuited or has become
disconnected, the device stops working.)
Power overload from the condenser fan
E9
(The cooling fan overloads the board beyond
the allowed limit. Possible cause: short circuit or
something is blocking the fan from rotating.)
battery-saver
has
activated.
ENGLISH
Troubleshooting
Power
Start the vehicle in order to recharge the
battery.
Take the device to an authorised dealer.
The presence of
indicate
management procedure for the compressor by
the electronic board. Only if the code continues
to be displayed contact an authorized dealer.
Take the device to an authorised dealer.
40
codes do not
E3
E4
E5
a malfunction,
but
is
a normal

Publicité

Table des Matières
loading

Table des Matières