1� About this document
– Please read carefully and keep in a safe place.
– Under copyright.
Reproduction either in whole or in part only with our consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in the document�
...
2� General safety precautions
!
Disconnect the power supply before attempting any work on the sensor�
• During installation, the electric power cable to be connected must not be live.
Therefore, switch off the power first and use a voltage tester to make sure the wiring
is off-circuit.
• Installing the sensor involves work on the mains power supply. This work must there-
fore be carried out professionally in accordance with national wiring regulations and
electrical operating conditions. (DE - VDE 0100, AT - ÖVE-EN 1, CH- SEV 1000)
3� IS 3360, IS 3360 MX, IS 345, IS 345 MX, IS 3180
Proper use
– IS 3360 MX and IS 345 MX are suitable for indoor ceiling mounting.
– IS 3360 and IS 345 are suitable for indoor and outdoor ceiling mounting.
– IS 3180 is suitable for wall mounting indoors and outdoors.
– The concealed versions are only suitable for installing indoors.
The motion detector is equipped with pyro sensors that detect the invisible heat
emitted from moving objects (people, animals etc.). The heat detected in this way is
converted electronically into a signal that switches a connected load ON (e.g. a light).
Heat is not detected through obstacles, such as walls or panes of glass.
Heat radiation of this type will, therefore, not trigger the sensor.
Optionally, all function settings can be made via the RC5, RC8 remote controls as well
as the Smart Remote. (➔ "7� Accessories")
26
Package contents for surface-mounted installation (Fig� 3�1)
Package contents for concealed installation (Fig� 3�2)
Product components (Fig� 3�3)
A Load module, power supply lead, surface-mounted
B Load module, power supply lead, concealed installation
C Designer trim, round or square
D Sensor module
E Shroud
Product dimensions
Surface-mounted / concealed (Fig� 3�4)
Surface-mounted / concealed (Fig� 3�5)
Surface-mounted / wall-mounted (Fig� 3�6) IS 3180
4� Electrical installation
The mounting location should be at least 50 cm away from other lights because heat
radiated from these may activate the system.
An optional corner wall mount (product no. 648015 black or 035174 white) is available
for mounting the IS 3180.
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N
= neutral conductor (usually blue)
PE
= protective-earth conductor (green/yellow)
= connection to the DALI BUS
Wiring example (Fig� 4�1/4�2)
– Surface-mounted installation
If the rubber seal is damaged, the cable entry openings must be sealed with an M 16 or
M 20 (at least IP 54) double seal cable gland.
For mounting the IS 3180 on the wall, a condensation water drainage hole (Ø 5 mm drill
bit) is marked next to the rubber seal. This must be opened if necessary.
Master/slave (Fig� 4�3)
The DALI sensor is suitable for use in master/slave networks. In this case, the DALI
sensor is the master, the DALI 2 input device is the slave. The master/slave config-
uration permits detection of movement in larger rooms or spaces (load connected =
master, no load = slave). The level of brightness prevailing in the room is only evaluated
at the master. The slaves report movements detected to the master. Lighting is only
switched ON and OFF by the master.
IS 3360, IS 3360 MX, IS 345
IS 345 MX
27