• Turn off the dehumidifier using the on/off switch (I / O), disconnect the power
adapter from the mains and then carefully remove the full water tank (6) from the
holder. Ensure that you do not spill any water when removing the tank. Empty the
tank.
• Put the water tank back into the dehumidifier and turn the dehumidifier back on
when needed.
• Turn off the dehumidifier after use and disconnect the mains plug from the power
socket. Empty the water tank (if necessary).

Maintenance and cleaning

• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as
these could damage the housing or even impair the functioning of the product.
• Turn off the device before cleaning and remove the mains plug from the mains
socket.
• Empty the water tank before cleaning the dehumidifier.
• Use a dry, soft and clean cloth to clean the product housing. Do not press too hard
on the housing, as this can lead to scratch marks.
• Use a long-haired, soft and clean brush to remove dust from the air inlet grille (5).
• Remove the dry air outlet grille (1) with a filter net from the dehumidifier. Dust can
accumulate on the filter net over a period of time. Remove the dust using a brush or
cloth. Insert the dry air outlet grille back into the dehumidifier.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.

Technical data

a) Dehumidifier
Input voltage/current..........................12 V/DC, 5 A
Dehumidifying capacity .....................250 ml/24 h at +30 °C / 80% RH
Water tank shut-off .............................At approx. 400 ml
Water tank capacity ...........................500 ml
Room size .............................................Up to 15 - 20 m²
Operating conditions ..........................+5 to +45 °C, 25 to 100% RH
Storage conditions..............................+5 to +75 °C, 25 to 100% RH
Dimensions (W x H x D)......................154 x 218 x 130 mm
Weight ...................................................approx. 820 g
b) Power adapter
Input voltage/current..........................100 - 240 V/AC, 50/60 Hz, 1.8 A
Output voltage/current .......................12 V/DC, 5 A
Protection class ..................................II
Power adapter and
total cable length ................................approx. 2.5 m
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
V2_0316_02-HK

Publicité

Table des Matières
loading

Table des Matières