28 - ENG
We recommend programming the lowest output frequencies in the modules
furthest from the amplifier, and successively programme higher output
frequencies. This achieves the best width-frequency response for the module.
10.3 Level of the ZF amplifier
In the field meter, tune the transponder with the highest output level and
adjust the level of the transponders with the regulator of the output signal
level (29).
WARNING, bear in mind the reduction of the maximum output level
depending on the number of transponders amplified (the TV input channels
are not amplified). The maximum work level is calculated by subtracting the
reduction indicated from the maximum output level indicated in the sheet of
characteristics (36).
TRANSPONDERS
1..8
9..16
17..24
25..32
11. UPGRADING THE UC PROCESSOR
It is possible to upgrade the UC processor. Please download the necessary
programs and instructions from the Alcad website:
If you do not have an internet connection, please contact your nearest Alcad
distributor or representative, or contact Alcad directly to request the
upgrade programs.
Installation and programming manual
REDUCTION OF
MAX LEVEL
- 7dB
- 9 dB
-11 dB
-12 dB
Fig. 10 - Adjusting the amplifier level
www.alcad.net
Tab. 6 - Reduction of the
output level