Supplied parts

The following parts make up the LP conversion kit:
ORIFICES/ORIFICES/ORIFICIOS
DTG30P875N*/DTG36P875N*
The all orifices' positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
RF
LF
RR
LR
Center
Install_DTG36P875N_DG68-01286A-00_EN+MES+CFR.indb 23
LR(WHT)
RR(YEL)
CENTER
Out(PURPLE)
In(GRAY)
LF(WHT)
RF(RED)
DG69-00549A
(PAD SHEET)
BTU Rate
Orifice size [mm]
11,500
1.04
7,500
0.83
4,000
0.62
7,500
0.83
14,500
In: 0.46 / Out: 0.74 (2 pcs)
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
RF
13,000
LF
9,500
RR
5,000
LR
9,500
Center
19,000
NOTE
Orifice markings:
115
115 – Denotes 1.15 mm orifice size opening.
Orifice size [mm]
1.64
1.40
1.01
1.40
In: 0.70 / Out: 1.30 (2 pcs)