3 - INSTALLATION

3.1 - LOCATION
• Protection index of the unit: IP 21.
• Select the location for the unit on the basis of the following criteria:
- the unit must be installed in a sheltered location,
- the unit must not be installed near the following:
GB
. sources of heat,
. combustible materials,
. return / air intake of an adjacent building.
- it is necessary to make sure that the free space around the unit is
provided (see the minimum dimensions on the drawing opposite),
- installation must be simple and make maintenance work easy,
- the unit must be secured to a wall able to support its weight.
3.2 - MOUNTING THE UNIT
• Remove the cover from the unit:
- remove the retaining screws (1 on each side and 1 on top) (1).
• Slide the cover upward (2), until the bottom edge of the covers is aligned
with the lower part of the rear support, then pull it towards you (3).
1
• Secure the unit to the wall. Refer to the position of the 4
mounting holes in the diagram opposite.
Use anchors and screws (not included) that are adapted
to the weight of the unit and the type of wall.
- Install the 2 screws in place in the upper holes (A) in
the wall.
- Hook the unit in place.
- Install the 2 screws in place in the lower holes (B).
2
1
1
Align the bottom edge of the cover with the
lower part of the rear support
Minimum clearance in front of the unit: 1 m
0 . 2 0
m
6
1 m
3
A
m m
4 6 0
B
m m
3 6 0