Sanyo SPW-W366HH58 Notice D'installation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

E) Pilot wire for electric convectors (if any)
- The pilot wire sends shut-down, "anti-freeze" (long term absence) or "Economy" mode instructions to the electric
convectors in zone 2, and possibly in the case of 1 floor zone or 1 terminal unit zone applications.
Convector control (not supplied) must be adapted to receive this type of signal (standard GIFAM 4).
Consult the manual of the electric convectors.
- 230 VAC signal from the heating board.
- 1.5 mm
2
single-pole cable adapted for the operating voltage.
- Max. number of convectors controlled by the pilot wire: 20.
-
To be connected to the heating board A1.
GB
- Note:
The electrical power supplied to the convectors must be the same as that of the module.
F) ECO signal for remote controls (if installed)
- In order to send reduced mode orders (Eco or standby) to the terminal unit remote control units in the case of
applications such as 1 terminal unit zone or 2 mixed zones.
- In the form of a potential-free contact which can used in VLV (Very Low Voltage), 2A max.
- To be connected to the heating board A1.
- Note:
The contact can control up to 10 RCC10 (70250051) or RCC20 (70250052) type controls.
Consult the terminal unit and remote control documentation to connect this contact.
CONTROL PART CONNECTION DIAGRAM
- Route the control cables on the right side of the board.
- Pass the pilot wire (230 V) on the left side of the board.
S1 C S2 C S3
5
4
3
CN8
CN1
1
2
N
U FP
230V
E
Pilot wire
Electric
convectors
(if any)
4
3
2
1
A1 C A2 C
2
1
4
3
2
1
5
4
3
CN7
CN6
CN2
CN3
3
1
2
3
4
1
2
3
4
R1 R2 R3 C
E1 E2 T+
T-
N
U
N
U
N
U
Q1
Q2
Q3
KM1 KM2 KM3 KM4
Power terminal strip XA
A3
H1
H2 H3
2
1
3
2
1
CN5
Heating
A1
board
CN4
1
2
3
4
D1 D2 +
-
KA1 KA2
F
ECO signal
(if any)
Control terminal strip XB
U1 U2
C
1
2
To Outdoor
Unit
12
N
U
Q4
D
Electrical
utility
OR
meter
Load shedding
(if installed)
R1 R2 +
A
Keypad / RCS -
TM80 BG display
unit (if any)
B
Outside
temperature
sensor
Control unit
BUS connection to
the 2-zone module,
ATK-WM2ZF or
ATK-WM2ZM
(if any).

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Spw-w486hh58Spw-w606hh58

Table des Matières