The HA-58 is a heat detector meant to discover cases of fire in the first phase. If the temperature rises, the
EN
HA-58 will start emitting a loud alarm tone of at least 85dB (A). It's advisable to test the heat detector weekly by
using the test button. Attention: This heat detector only signals when the temperature rises to 55˚C or higher. It
doesn't directly detect smoke or fire. Save this manual in a secure location, like the fuse box cabinet.
RECOMMENDED INSTALLATION LOCATIONS FOR THE HA-58:
•
Install the heat detector in areas where you cannot place a smoke detector. Ensure that it is placed in a location that
ensures that, if there would be a fire nearby the detector, the escape route is still accessible.
•
Use multiple detectors to increase your safety and to ensure an escape route will be available in case of fire.
•
It's advisable to place one heat detector in every location where there is no smoke detector.
•
Place at least one heat detector in the kitchen and garage, where equipment present may cause fire.
•
Both heat and smoke will first move upwards, to the ceiling. Then it will travel horizontally. Wall-mounting may technically
be possible but will result in slower alarm.
•
When mounting the detector to the ceiling, place it at a minimum distance of 50 cm from any wall and 61 cm from any
corner. Due to natural air flow, such corners will slow or prevent detection of heat.
AVOID THE FOLLOWING LOCATION INSTALLATIONS:
•
Keep away at least 3 meters from any cooking apparatus.
•
Do not place in the bathroom; hot showers may cause false alarm.
•
Do not place near a fan or near the exhaust of an airconditioner or heater.
•
Do not place in the nook of an A-shaped ceiling.
•
Do not place in rooms where the temperature can reach below 0°C or beyond 45°C.
•
Do not paint the heat detector and do not cover it in any way,
INSTALLATION INFORMATION:
Install the ceiling plate on a location fitting the description above using plugs and screws. Remove the plastic foil from
the battery that is placed inside of the detector, plug it in the cable located inside the battery compartment and place it
firmly inside the compartment. Once a battery is placed, you should be able to place the detector on the ceiling plate
and rotate it easily. Test the detector first by holding the "Test"-key for 2 seconds.
The RED LED will blink every minute to show the detector is still operational.
9V BLOCK
60 cm minimaal
dode
luchtruimte