Malfunction display and solutions

When the washer is in trouble, please contact local service office or the sales service
department of our company and the customer should not dismantle the machine
without permission.
If the washer can not work normally, and the abnormal indication is shown in the digital
display window or the machine alarms, please check and correct as follows.
Fault
Cause of fault
Water injection for about
Alarm for
30 minutes, but do not
water inlet
reach preset water level
Open the lid after starting
the delay time. Open the lid
Alarm for
when the washer is spinning.
opening lid
Open the lid when entering
into the child lock state.
Imbalance
alarm
After draining for 10
Drain
minutes, does not finish
draining.
alarm
Water level is higher than
Overflow
rated overflow level
alarm
Not normally open or
Door-lock
unlocked door
failure
Note:
1: alarm removed, the return to the status before the alarm; E3 failures appear in the same trip.
2: overflow alarm, automatic water drain valve open until the manual intervention contact failure.
Alarm of the
Indication
Stopping alarm
buzzing sound
"E1" flares, and
other lights are
turned off.
"E2" flares, and
other lights are
turned off.
"E3" flares, and
other lights are
turned off.
"E4" flares, and
other lights are
turned off.
"E5" flares, and
1:Power off
All water lever
2:repair
lights flash .
the door can be open only by
pull up the power when the
door is locked, and it can
"E6" flares,
power-off and alarm-cleared
by press the power key when
the door lock is open.
18

Technical specifications

Technical specifications
601X615X1015
Current
4.2A
value
120
45kg
2.5Cu.ft
Drum Size