Model Specifications; Main Specifications - NGS Technology FORTRESS V2 Serie Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
ENGLISH

MODEL SPECIFICATIONS

FORTRESS 600 V2
400VA / 240W
FORTRESS 900 V2
600VA / 360W
FORTRESS 1200 V2
800VA / 480W

MAIN SPECIFICATIONS

Model
BASTION 400 / 600 / 800
DC voltage of long backup
12VDC
Type of load
Computer, displayer
Input voltage
230V
Input frequency
50Hz
Output voltage
230V
Output frequency
50/60Hz 0.5Hz (in battery mode)
Power factor
PF=0.6 (when input range -35% to
-23%, PF=0.45)
Backup time
5-10 minutes
(depends of the load)
Transfer time
10ms
Short-circuit protection
Circuit breaker, limited output
currency in inverter mode
Efficiency of power
>80% in inverter mode
Temperature
0°C ~ 40°C
Humidity
10% ~ 90%
Display
LED display: AC, charging,
inverting
INTRODUCTION
Battery: 1x 12V/4.5Ah
Off-line UPS LED
Battery: 1x 12V/7Ah
Battery: 1x12V/9Ah
1. Battery charging Led: it lits when the UPS is plugged to the mains.
2. Power failure Led: it lits when the UPS detects a power cut.
3. Power ON Led: it lits when you turn on the UPS. It shows the power
4. ON/OFF button: turns UPS on and off.
2
1
3
4
output is working.
Press and release to turn on
Press and release to turn off