1. For shipping purposes, the UV lamp is shipped in a separate cardboard
tube. Carefully remove the UV lamp from the shipping tube being careful
not to touch the "glass" portion with your fingers. Insert the UV lamp
into the quartz sleeve and chamber making sure the connection end is
inserted last. Mount the disinfection system to the wall with the supplied
clamp (1 clamp on all 1.5 and 2 gpm units and 2 clamps on all 3, 6, 10
and 15 gpm units). If required, a double-end clamp can be purchased
from your dealer to affix to an RO membrane.
2. If the disinfection system is to be hard plumbed, make sure you leave
enough clearance in front of the lamp connector to facilitate lamp
service (a length equal to the length of the unit should suffice).
3. Various connection methods can be used to connect the water source to
the disinfection system, however union type connectors are
recommended. The use of a flow restrictor device is strongly
recommended when installing your disinfection system in order that the
manufacturers recommended flow rate not be exceeded. These flow
restrictors are available from your dealer. In addition, the use of a by-pass
assembly is recommended for emergency use of untreated water when
your disinfection system is being serviced.
Note: When the UV unit is returned to service after being on by-pass the
complete water system must be sterilized once again with chlorine
(household bleach) to destroy any contamination that may have
entered the distribution system while on by-pass. DO NOT SOLDER
CONNECTIONS WHILE ATTACHED TO THE DISINFECTION SYSTEM
AS THIS COULD DAMAGE THE O-RING SEALS.
4. Prior to connecting the power source, check all connections to ensure
that they are indeed secure, turn on water supply and check for any
leaks. If satisfied that there are no leaks, proceed with the following
steps.
5. To properly ground the stainless steel generating chamber, attach the
green wire coming from the power source to the grounding lug on the
UV chamber. Remove the green cap nut and slide the eyelet connector
onto the screw. Fasten the cap nut to the screw with a 5/16" wrench.
6. The power source provided with your disinfection system must be
located within (5) feet of an electrical outlet. DO NOT USE AN OUTLET
THAT CAN BE SWITCHED OFF (IE. A WASTE DISPOSAL OUTLET). Attach
the lamp connector to the UV lamp, slide the connector over the
aluminum retaining nut (see section 3 & 4 on page 6 for details). Plug
the ballast into the outlet and ensure the POWER-ON LED is illuminated.
The audible ballast will enter a self test mode when power is first applied
to verify ballast operation.
Note: If ballast enters alarm condition, power must be removed for 30
seconds to allow ballast to reset.
Note: As the system requires time to reach its full operating capacity,
please allow the disinfection system to operate 3 - 5 minutes prior to using
the water from the unit. In addition, to clear any air or debris from the
system, open the faucet and allow water to run through the disinfection
system for 2 - 3 minutes (when using an RO application, run the water for
30 - 45 seconds).