Technical Data - WATERKOTTE F41449 Planification Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical data

13 Technical data
Electronic compact domestic water heater
Output capacity (55 °C buffer temperature / domestic
water heating from 10 °C to 50 °C)
Output capacity (55 °C buffer temperature / domestic
water heating from 10 °C to 40 °C)
Max. power input circulation pump
Power input controller
Residual pressure primary and primary flow rate
(tapped water with 10 °C/50 °C and 55°C water tank).
Total approximate maximum length of pipe to install
between domestic water heater and storage tank
(please calculate exactly taking into account the el-
bows and other parts)
Operating limit
Max. Operating pressure primary (tank-HP) / second-
ary (domestic water):
Electrical data 1x 230 V, 50 Hz
Max. operating current
Main fuse on site
Dimensions, weights, connections
Weight of unit
Connections:
Dimensions l x h x p
24.10.2018
For individual technical data and filling capacities of your domestic water
heater, please refer to the type plate.
* You can tap water over about 41 l/min but the display stay at about 41 l/min
** In these variants, we recommend 28x1,5 copper pipe.
17 / 20
Copyright  2018 by: WATERKOTTE GmbH Subject to changes.
Unit
38 kW
54 kW
l/min
13,7
19,3
l/min
21,7
28,2
W
W
mWC
4,9
4,8
m³/h
1,0
1,3
90 me-
59 me-
ter
ter
22x1
22x1
copper
copper
pipe
pipe
°C
bar/bar
A
A
kg
21
23
Flat sealing 1"
mm
670 x 375 x 182
80 kW
100 kW
28,7
35,8
40,3
49,5*
76
1
3,1
2,0
1,9
2,3
20 me-
20
ter
meter
22x1
22x1
copper
copper
pipe**
pipe**
90 °C
2,5 / 10
2
10
25
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F41448F41450F41451

Table des Matières