13. Troubleshooting
DEFECT
1.
The boiler is full of water
and the water flows out
of the safety valve.
2.
The safety valve trips,
venting the steam. The
pressure gauge indicates
a boiler pressure higher
than 1.8 bar.
3.
The machine was started
properly but the water in
the boiler does not warm
up.
46
CAUSE
remains open.
faulty.
control system (the heating
element is always powered).
bar safety valve tripped).
defective or not connected.
1.
SOLUTION
and contact an authorized qualified
technician.
must check the correct operation of
the filling solenoid, the electronics
controlling the automatic level and
any faults in the manual filling valve.
power switch to position 0 and
contact an authorized qualified
technician.
must check the electrical wires
powering the heating element, the
temperature control system switch
and the safety thermostat.
position 2.
must check the electrical wires
powering the heating element.
Moreover, it is important to check
whether the thermostat tripped the
heating element safety and to check
its correct operation.