SEcTIoN 2
2 .
Connect lines from plumbing box to the power source . Open top front cover to gain access to the torch connections .
chassis ground
3 .
Thread the five service lines of the PT-26 torch through bushing at upper left corner of the front panel and connect them
to the matching fittings on output terminal . Hose connections should be wrench-tight . Make sure plug of the switch
lead is firmly locked in place . Then close hinged cover .
2
2
Power/Coolant adapter
4
4
Water IN (+)
4
2
Water oUT (-)
(Pilot arc)
(Electrode)
Interconnection Diagram - Front of ESP-150
DEScRIPTIoN / INSTallaTIoN
Pilot arc adapter
(P/N 0558009992)
(P/N 36743)