7.2 Menu structure

Parameter change: The menu is accessed using the "Menu"
key. In this menu, changes can be made to parameters. The de-
sired menu item is selected with the arrow keys "UP" "DOWN".
The submenu is accessed using the "OK" key.
Menu block
Menu item
Basic settings
during commissioning:
language
date
time
set temperature
lower
settings
time
date
language
signal tone
backlight
factory settings
type
hot water
set temperature
lower
hysteresis
electrical heater
ventilation
level manual
level 1
level 2
level 3
service reset
time program
therm. disinfect.
lower 1
EN-12
Parameter
Value
00:00
DD:MM:YYYY
ENGLISH
ENGLISH
FRANCAIS
ITALIANO
POLSKI
0 % ... 50 % ...100 %
DHW 300VD+
25 °C ... 45 °C ... 85 °C
15 °C ... 25 °C ... 40 °C
2 K ... 3 K ... 10 K
Mode
ECO
AUTO
Delay
2 h ... 12 h...24 h
Boost period
1 h ... 4 h ... 8 h
Boost set temp.
25 °C ... 60 °C ... 85 °C
0* / 1 / 2 / 3 / Auto
30 ...60 m³/h...300 m³/h
30 ...90 m³/h...300 m³/h
30 ...120 m³/h...300 m³/h
yes / no
start
00:00 ... 23:59
Days
Mo ... Su
Set value
60 °C ... 65 °C ... 85 °C
start
00:00 ... 23:59
end
00:00 ... 23:59
451905.66.07 · FD 9912
In this submenu, the parameter that is to be changed can be se-
lected (also using the arrow keys). The "OK" key is used to se-
lect the marked value, which can then be changed via the arrow
keys. The entry is completed by pressing the "OK" key again.
Setting the language
Sets the current date
Sets the current time
Sets the desired domestic hot water temperature
Sets the reduced domestic hot water temperature
Time setting (24 hour time display)
Date setting (Day:Month:Year)
Language selection
on
Setting key tone on / off
off
Setting display backlight
Factory setting reset
Domestic water heat pump DHW 300VD+
with defrost function, additional heat exchanger and ventilation
Sets the desired domestic hot water set temperature
Sets the minimum hot water temperature, which should also not be
undershot for the duration of a programmed lower process.
Sets the switching hysteresis
ECO: Only switches in the event of an error and with PV b./t., ther-
mal disinfection on
The electric heater is automatically switched on if the domestic hot
water set temperature is not reached in heat pump operation.
Boost: adjustable time (once, manual switch-on, runs regardless of
the Auto/Eco setting)
Boost: adjustable set temperature
Ventilation level if no time program is active/ basic operation
Volume flow in level 1
Volume flow in level 2
Volume flow in level 3
Confirmation of the maintenance and restart of the time interval
counter
Thermal disinfection
Setting of the start time for a thermal disinfection, duration up to 4
hours, ends at max. 23.59 hours
Sets the day on which thermal disinfection should be activated
Sets the set temperature for thermal disinfection.
Sets the start time for lowering the domestic hot water set temper-
ature
Sets the end time for lowering the domestic hot water set tempera-
ture