TROUBLE SHOOTING

Problem
Cause
Solution
Unit is not plugged in
Plug in the unit
Machine does not work
Room temperature is <5°C or above 35°C
To protect the machine, use it only when ambient
(<41°F, >95°F).
temperature is between 5 and 35 degrees.
Machine runs but does not
The humidity set point is 2% higher than ambient
Reset the humidity to a lower set point .
dehumidify
humidity.
Filter mesh is jammed
Clean the filter mesh
Reduced dehumidifier capacity
Air-in and/or Air-out louvers jammed.
Clear the blockage of the Air-in and/or Air-out louvers.
Clean filter according to instructions or clean the louver
No air inlet
Filter mesh or air-in louver jammed.
blockage
Machine situated on an incline or decline slope
Move to a flat ground
Loud Operation
Filter mesh is jammed.
Clean filter mesh according to instructions
Cautions: Switch off the unit and unplug it immediately if anything abnormal happens. Contact a qualified electrician.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact you local government for information regarding the collection systems available.