Safety • Installation
Important Safety Instructions
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential
for personal injury!
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to
personal injury.
Carefully read and follow all safety instructions in this
manual and on pump .
Keep safety labels in good condition. Replace missing or
damaged safety labels.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm.
1. Read this manual carefully. Failure to follow these
Instructions could cause serious bodily injury and/or
property damage.
2. Check your local codes before installing. You must
comply with their rules.
3. Vent septic tank according to local codes.
4. Do not install pump in any location classified as
hazardous by National Electrical Code, ANSI/NFPA
70-1990.
Risk of electric shock . Can shock, burn
or kill .
•
Do not lift pump by power cord. See Cord Lift Warning.
•
During operation, the pump is in water. To
avoid fatal shocks, proceed as follows if pump
needs servicing:
5A. Disconnect power to outlet box before
unplugging pump.
5B. Take extreme care when changing fuses. Do not
stand in water or put your finger in fuse socket.
5C. Do not modify cord and plug. When using cord and
plug, plug into a grounded outlet only. When wiring
Performance
MODEL
5 (1.5m)
CLW2800
3180 (12,038)
For parts or assistance, call CountyLine Customer Service at 800-535-4950
to a system control, connect pump ground lead to
system ground.
6. Do not run pump dry. Dry running can overheat
pump, (causing burns to anyone handling it) and will
void warranty.
7. Pump normally runs hot. To avoid burns when
servicing pump, allow it to cool for 20 minutes after
shut-down before handling it.
8. In normal service, motor should not need oiling.
Motor has been filled at the factory with a special oil.
Installation
NOTICE Install pump on a hard, level surface (cement,
asphalt, etc.). Never place pump directly on earth, clay
or gravel surfaces.
Pi ping – Effluent Applications (3/4" or
Less Solids)
Piping must be 1-1/2" minimum to carry volume of
pump discharge. Check local codes to determine if a
check valve is required in your system. In cold climates,
check valves are not used to prevent effluent from
freezing in piping.
If a check valvue is required, use a 1.5" (3.8 cm) swing
check valve in pump discharge to prevent backflow of
liquid into sump basin. Check valve should be a free
flow valve that will easily pass solids.
NOTICE For best performance of check valve when
handling solids, do not install it with discharge angled
more than 45° above the horizontal. Do not install check
valve in a vertical position as solids may settle in valve
and prevent opening on startup.
Drill a 3/16" (4.7mm) hole in discharge pipe about 1"-2"
(2.5 - 5.1cm) above pump discharge connection (but
below check valve) to prevent airlocking the pump.
If using as a sump pump, a check valve is recommended.
GPH (Liters) At Discharge Ft . Of Head
10 (3m)
15 (4.6m)
2700 (10,221)
2100 (7,949)
20 (6.1m)
25 (7.6m)
1500 (5,678)
750 (2,839)
2