8. Feed the wires, now at the rear of the mounting bracket, through the 1/2-inch conduit fitting
(installed in step 4).
9. Attach the mounting bracket and light assembly to the wall with 1/4-20 x 1-1/8-inch
machine screws (supplied). Insure that the backplate is positioned behind the mounting
bracket flange as shown in figure 1.
Electrical splices must be made within a condulet box (customer-supplied).
10. Using the length of leads extending out of the 1/2-inch conduit fitting as a guide, determine
the length of conduit necessary for the installation. Ensure that an adequate length of wire is
left to make splices in the condulet.
11. Install conduit and condulet. Connect supply source wires to light wires at condulet.
C. Kit Contents List.
Qty.
1
1
1
1
2
4
1
Description
Mounting Bracket
Bushing, Threaded
Backplate
Bushing, Reducer
Screw, Set, Hex Socket, 1/4-20
Screw, Machine, 1/4-20 x 1-1/8"
Instruction Sheet
NOTE
-2-
Part Number
8459D088A-0l
8459109
8459C099
8459108
7008A021-04
7000A074-18
8459A094