STEP 2: MOUNT THE RECEIVER
WA R N I N G
The receiver must be correctly installed to work properly. The
receiver should be mounted in a location that is as clean and
TO PREVENT SERIOUS INJURY
dry as possible while also allowing access to the
OR DEATH FROM EXPLOSION:
programming button. The mounting location must also
• Do not drill into gas tank.
provide clearance for the wire harness to attach to the
• Verify the area is clear behind the
receiver.
mounting location before drilling.
Best locations for the receiver will vary depending on the
vehicle. Typical locations include: under dash, on inner
fender inside engine compartment. Avoid mounting receiver
near battery or exhaust manifold. Maximum operating
temperature is 220 F˚ (104˚C).
Mounting Steps:
1. Determine the mounting location.
2. Mount on a flat surface, mark and drill a minimum of two
(2) mounting holes, one on each side of the receiver.
3. Loosely attach the receiver using 1/4-inch or M6 bolts
and locknuts.
4. Tighten fasteners.
Programming LED
Programming button
WA R N I N G
TO AVOID SERIOUS INJURY OR
DEATH FROM ELECTRICAL
FIRE:
• Never route electrical
cables:
- Across any sharp edges.
- Through or near moving
parts.
STEP 3: ROUTE THE HARNESS
- Near parts that become
hot.
Routing Steps:
• Always insulate and
1. Plan a route for the wire harness between the receiver and
protect all exposed wiring
the winch control pack.
and electrical
2. Route harness.
terminals.
Warn Industries, Inc.
6
Minimum of one fastener on each side
STEP 4: CONNECT THE WIRING
WA R N I N G
Note: Refer to Figure 1.
TO AVOID SERIOUS INJURY OR
1. Connect the wire harness to the receiver.
DEATH FROM ELECTRICAL
2. Connect the 90 degree plug on the wire harness into the
FIRE:
winch control pack.
• Never route electrical
3. Use tie wraps to secure the wire harness.
cables:
- Across any sharp edges.
- Through or near moving
parts.
- Near parts that become
hot.
• Always insulate and
protect all exposed wiring
and electrical
terminals.
Figure 1: Wiring Installation Diagram
WARN Wireless Control Installation Guide 7