Samsung DV457E Série Manuel D'utilisation page 23

Masquer les pouces Voir aussi pour DV457E Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Review the "Electrical requirements" section on page 18.
BEFORE OPERATING OR TESTING, follow the grounding instructions in the "Grounding"
section on page 18.
WARNING
Remove the terminal block cover plate.
Insert the power cord with a UL-listed strain relief through the hole provided in the cabinet
near the terminal block.
Do not loosen the nuts already installed on the terminal block. Be sure they are tight.
Use a 3/8" (1 cm) deep well socket.
6. Review the "Gas requirements" section on page 17. Remove the pipe thread protective
cap. Apply a pipe joint compound or about 1 1/2 wraps of Tefl on tape over all threaded
connections.
Connect the gas supply to your dryer. An additional fi tting is required to connect the 3/4" (1.9
cm) female thread end of a fl exible connector to the 3/8" (1 cm) male threaded end on the
dryer.
Securely tighten the gas line fi tting over the threads.
Turn on the gas supply.
Check all gas connections for leaks using a soap solution.
If bubbles appear, tighten the connections and recheck. DO NOT use an open fl ame to
check for gas leaks.
DV457E(G)-02836E-03_EN.indd 23
DV457E(G)-02836E-03_EN.indd 23
U.S. MODELS:
RISK OF ELECTRIC SHOCK - All U.S. models are produced for a 3-WIRE SYSTEM
CONNECTION.
The dryer frame is grounded to the neutral conductor at the terminal block.
A 4-WIRE SYSTEM CONNECTION is required for new or remodeled construction,
mobile homes, or if local codes do not permit grounding through neutral. If the 4-wire
system is used, the dryer frame cannot be grounded to the neutral conductor at
the terminal block. Refer to the following instructions for 3 and 4-WIRE SYSTEM
CONNECTIONS.
A strain relief must be used.
The pipe joint compound must be resistant to the actions of any liquefi ed petroleum
gas.
Installing your dryer _23
2012-12-04
2012-12-04
6:44:40
6:44:40

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dv457eg série

Table des Matières