Safety Precautions; System Operation - golmar ART 1/G2+ Guide Rapide

Masquer les pouces Voir aussi pour ART 1/G2+:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ART 1/G2+ HANDS-FREE AUDIO TERMINAL

SAFETY PRECAUTIONS

-
Always disconnect the power supply before making modifications to the device.
-
The fitting and handling of these devices must be carried out by
-
The wiring must run at least 40 cm away from any other wiring.
-
Do not overtighten the screws on the connector.
-
Install the
ART 1
terminal in a dry protected location free from the risk of dripping or splashing water.
-
Do not place in humid, dusty or smoky locations, or near sources of heat.
-
Before connecting the device to the mains, check the connections between the door panel, power
supply and Nhea terminals.
-
Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
-
ART 1
hands-free audio terminal with simplified installation (non-polarised 2 wire bus).
- Up to 4
ART 1
terminals/monitors per apartment (master, slave 1, slave 2 and slave 3).
- Up to 32 apartments/ART 1 terminals in mixed installations with monitors
- Up to 128 apartments/
ART 1
terminals per installation
- Completely private conversation.
- Call reception volume control: min, med, max and off (do not disturb).
- Audio volume control during communication process (4 different levels).
-
"HZ" i
nput for calls from
apartment front
door.
.
- Output to auxiliary call repeater (maximum 50mA/12Vdc).
-
Up to 6 d
ifferent ringtones to identify the origin of the call (door panel, intercom
front door of the apartment).
- Button
for starting/stopping communication. In standby: 2 short press to "intercom" calls (within
the same apartment) and press for 3 seconds to "autoswitch-on" function.
- Button
for lock release 1 activation. In standby: activate/ deactivate "Doctor mode"
- Button
for lock release 2 activation/ staircase light activation (SAR-G2
- Button
for tone call volume control, "do not distrurb" mode/ configuring ringtones/ communication call
volume control (ART 1 speaker) & in case of call forwarding, cancel call transfer (with ART 7W monitor).
- Button
for guard monitor calls (if exist).
- DIP switches for setting the terminal's address (call code), master/slave and end of line.

SYSTEM OPERATION

-
To make a call, the visitor needs to press the button for the apartment, an audible tone indicates
that the call is being made and LED
on the door panel illuminates. If vocal synthesis is enabled,
a 'Call is in progress' message appears indicating that a call is being made. At this moment, the
apartment's terminal(s) receives the call. If another apartment is called by mistake, press the
button for the correct apartment and the first call will be cancelled.
- Upon receiving the call,
the push button
answered within 40 seconds, LED
will turn off and the channel will be freed.
-
To establish communication, press button
will turn off and the led
will
turn on
.
-
Communication will last for one and a half minutes or until button
communication has finished,
door panel
LED
synthesis is
enabled
, a 'Communication is finished' message will indicate that the call is over.
-
To open the door, press button
(if it exists and, to open the second door, press button
during the call or communication processes: one press activates the lock release for seconds
and LED
on the door panel will also illuminate for
'Door
is op
en' message will be indicated on the door panel.
-
Description of the function buttons can be found on p. 3.
( )
*
For more information, see T
" ART 1/G2+"
https://doc.golmar.es/search/manual/5012
25
29
authorised personnel
.
(EL632 G2+ SE module)
(EL6 2 G2 sound module required).
4
+
.
, guard monitor
+ &
SAR-12/24 modules required).
LED of the terminal(s) will blink white. If the call is not
on any terminal in the apartment.
Door panel LED
is pressed again. When
will turn off and the channel will be freed. If vocal
3
3
seconds. If vocal synthesis is enabled, a
user manual (code 5012
25
29).
2
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
( )
DESCRIPTION OF THE TERMINAL
*
Description:
AUX
a.
Speaker.
b.
Function push buttons.
c.
Raised dots for the visually impaired people.
.
In call
/communication
Above this raised dot is the 'Start/ nd communication'
button.
Above these raised dots is the 'Door opening' button.
( )
*
Function push button:
Start/stop communication button.
press to "intercom" call (within the same apartment) and
or
press for 3 seconds to "autoswitch-on" function.
In standby: short press, it allows to change tone call volume,
on every short press terminal reproduces the selected
volume (cyclic min/ med/ max/ off "do not disturb"). In
communication: on every short press, it allows to change
the speaker of the ART 1 audio volume (cyclic 4 audio
levels). Other settings see "TART 1/G2+ user manual.
( )
*
Function push button status LED:
-
During call door panel, guard or intercom process
blink (white color).
Terminal in communication
on (white color).
-
"Do not disturb" mode
: Led switch on (red color).
process (with ART 7W monitor): Led blink (red color).
"Default tones & tones volume": Led blink 5 times (red color).
-
"Doctor mode":
Led switch on (red color).
( )
*
Description of the DIP switch and conf guration of the
Dip1 Dip :
-
7
Sets the
terminals
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
terminal code is the sum of the values of the switches set to ON.
Important:
Apartment 1 (Dip1 to ON & Dip2-Dip7 to OFF).
Apartment 128 (Dip1-Dip7 to OFF).
.
Dip -Dip :
8
9
These define whether the
.
Master
ON
)
1
2
3
4
5
6
7
8
9 10
.
.
Dip
10 Configures the end of line. In installations with terminals only, it must always be in the OFF position. In
:
mixed installations of monitors with
which the BUS cable ends and leave in the OFF position for intermediate terminals.
.
( )
*
IMPORTANT: ART 1/G2+ terminal in
manual for Kit features as maximum number of apartments and monitors/ ART 1 G2+ terminals.
( )
*
For more information, see T
https://doc.golmar.es/search/manual/5012
EN
a
e
b
f
g
b
h
i
b
d
e
c
d.
Microphone.
e.
Wall mounting connector fixing (x4)
f.
Configuration switches.
g.
Golmar use.
:
h.
Bus connection terminals.
E
i.
Apartment front door button input.
j.
Auxiliary call repeater output (max. 50mA/12Vdc)
During the call or communication processes: one press
In standby:
2 short
will activate the lock release 1
button for 5 sec. to activate/deactivate the "Doctor
mode" function.
During the call or communication processes: one press
will activate the lock release 2
button for 3 sec. to activate the
G
2+ &
SAR-12/24
default tones & tones volume (led
Description connection terminals:
: Led will
SA: (Red)
: Led switch
GND: (Black)
Call forwarding
HZ: (
HZ: (
BUS
connection
i
ART 1/G2+
terminal address (code):
Building / Villa (Nexa Door Panel)
Note:
address (addresses to
1
128
).
Mixed installations with monitors (addresses 1 to 32).
Table of values
Switch number : 1 2 3 4 5
6
7
Value when ON 1 2 4 8 16
:
32 64
Example: 0+ 0+4+0+ 16 0+0
terminal
is master or slave. Each apartment must have
Slave 1
Slave 2
ON
ON
1
2
3
4
5
6
7
8
9 10
1
2
3
4
5
6
7
8
9 10
ART 1/G2+
terminals in the same apartment, set to ON for the terminals in
Villa installation with SOUL door panel
, see corresponding Kit Soul user
" ART 1/G2+"
user manual (code 5012
25
25
29
3
ART 1/G2+
12210140
V03
WARNING
TO PREVENT
FIRE OR ELECTRIC SHOCK,
DON'T EXPOSE THIS DEVICE
TO RAIN OR MOISTURE
MADE IN CHINA
j
BUS
HZ
GND
SA
OFF = 0 | ON = 1
DIP 1 to 7
DIP 8,9
Monitor address
00 - Master
10 - Slave 1
DIP 10
01 - Slave 2
End of line resistor
11 - Slave 3
GOLMAR S.A. C/ Silici, 13. 08940-SPAIN
. In standby press the
:
. In standby
: press the
staircase
light the
(
SAR-
modules required 5 short press to
).
blink 5 times).
(Auxiliary call repeater
output
, max. 50mA/12Vdc).
Red
)
(Door bell connection).
Black
)
(non-polarised)
.
ON
1
2
3
4
5
6
7
8
9
10
+
= 20
only
one master
terminal
.
Slave 3
ON
1
2
3
4
5
6
7
8
9 10
29).
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Terminal art 1/g2+

Table des Matières