1
1.5
Technical specifications
• Mains voltage/frequency:
230V / 50Hz
• Mains power fuse protection:
10 A medium time-lag min.;
16 A medium time-lag max.
• Power cord:
Cable 3.5 m long, 2-core (2 x 1 mm
031-0324 plug CEE 7/17, power socket type EF
031-0335 plug type J, power socket type J
• Extension lead:
max. 10 m with core cross-section of 1.5 mm
• Pulse repetition rate:
max. 20 shots/min, S2 30 min
• Electrical pulse generator:
radio-interference-suppressed
• Temperature range:
-10°C to 40°C
• Dimensions:
205 mm high, 233 mm long, 56 mm wide
• Weight:
1640 g
• Noise emission:
measured in accordance with EN 60745-1
A-weighted sound pressure level
L
= 85 dB(A); uncertainty K
pA
A-weighted sound power level
L
= 96 dB(A); uncertainty K
WA
Wear ear protection!
We reserve the right to make technical modifications and improvements in the interest of advancing our products.
12 / 96
2
)
2
2.5 dB(A)
pA =
2.5 dB(A)
wa =
• Vibration:
Total vibration value measured
in accordance with EN 60745-1
Vibration emission value ah = 3 m/s
uncertainty K = 1.5 m/s
• The total vibration value stated and the noise
emission level stated were measured on the
basis of a standardised testing method and
can be used for comparing one power tool with
another.
• The total vibration value stated and the noise
emission level stated can also be used for mak-
ing a preliminary estimate of load.
Warning:
• While actually using the power tool, vibration
and noise emissions may vary from the values
stated. This will depend on the way in which
the power tool is used, in particular the type of
workpiece it is being used for.
• To protect the operator, define additional safe-
ty measures based on an estimate of vibra-
tion load under actual operating conditions
(taking into account all parts of the operating
cycle, such as cycles in which the power tool is
switched off, and cycles in which it is switched
on but not operating under load).
2
;
2