SAFETY CHECK
WARNING : ONLY AN AUTHORIZED GAS TECHNICIAN SHOULD INSTALL THIS PRODUCT.
Check for leaks
All connections on the patio heater have been
checked for leakage at the factory. During
transportation and handling, some connections
may have loosened. Follow these steps to check
the gas hose/regulator/cylinder connections:
1) Make a leakage solution by mixing 1 part liquid
dish soap and 3 parts water.
2) Spoon or brush several drops (or use a squirt
bottle) of the solution onto the hose connection,
regulator, and cylinder connection.
3) Turn on the gas cylinder valve. Inspect the
connections and look for bubbles.
4) If no bubbles appear, the connection is safe.
5) If bubbles appear, there is leakage. Loosen
and retighten this connection. If the connection
still leaks, please call our toll-free service line
at: 1-866-814-0585.
Note:
1) The cylinder supply system must be arranged
for vapour withdrawal.
2) The cylinder used must include a collar to
protect the cylinder valve.
The hose assembly must be replaced before
operating the appliance if there is
evidence of excessive abrasion or wear, or if the
hose is damaged.
At least once a year, a complete inspection of the
entire gas path components should be performed.
If parts need to be replaced, perform a leak
test after reassembly. These procedures should
be performed by a professional technician.
13
Regulator and cylinder
connection