ARC1 Mini Mullion reader
MA1 OEM Module
Installation instructions
ARC1-XY
ARC1S-XY/PH5
ARC1S-XY/BT1
Outputs cable: 3 m
A
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply:
Max. consumption at 12 Vdc:
Communication:
RS485 (L+ & L-) / TTL (Wiegand / Clock and Data)
Connector output:
- 8 female stamped crimp terminals 28-22AWG (Wurth Electronik 62400113722DEC)
- 8 points female dual-row terminal housing (Wurth Electronik 624008213322)
(use Crimp Hand Tool
Cable output:
TRANXALARM - 8x0,22mm
Protection:
IP65 classified reader
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (SCB / OCB) or controlled by the remote system with a 0 Vdc
Led 1
Led 2
respectively on the "
", "
Tearing is detected by an accelerometer. When the reader is wrenched:
•
for R/S 31: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
for R/S 33 and OSDP
▪
TM
for W33: the reader will perform the operations configured with the SSCP
▪
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
R and S readers are configurable with SCB RFID / Virtual configuration card.
OSDP
readers are configurable with OCB RFID / Virtual configuration card or with FileTransfer command.
TM
▪
If the SCB/OCB is compatible with the reader's firmware, the LED lights green and the buzzer beeps five times.
▪
If the SCB/OCB is not compatible with the reader's firmware, the LED lights red and the buzzer is activated for 1 s.
If the SCB/OCB key is different from the reader's key: no reaction.
▪
Caution: set your reader with your own company key.
On power-up, the reader enters an initialization phase:
1.
Activation of the white LED and buzzer for 100 ms.
For read-only readers and OSDP
2.
Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3.
For serial R/S reader only: the orange LED flashes 20 times: waiting for an update.
4.
For Bluetooth
reader only: Activating white fixed LED during Bluetooth initialization.
®
5.
Activation of the default LED (read-only: flashes blue, OSDP
Caution: at the reader Bluetooth (BT1) powering, make sure that nothing is in an area of at least 10 cm / 3.94 in. around the reader (ex. No hand in front
of the reader...).
Connection
- Press the orange part to open.
- Insert the wire.
- Release the orange part.
- Check that the wire is correctly clipped.
▪ The supply voltage at the reader's connector should be between +9 Vdc and +15 Vdc.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference, depending on their radiation level and
the proximity of the reader.
▪ Recommended distance between two readers: parallel plane: 15.8 in – same plane: 15.8 in – perpendicular plane: 11.8 in.
▪ Recommended distance between two Bluetooth
▪ Place the reader at a height of less than 2 meters / 78.74 inch (standard UL/IEC 62368).
▪ If the reader is fixed on a metal surface, it is possible to have a reduction in the reading distance.
▪ Use a ferrite (two-way) for the cable (power supply and data).
▪ By design, the reader can be installed indoors and outdoors.
▪ BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
▪ Operating temperature: -4 °F to 158 °F / -20°C à +70°C.
STid reserves the right to make change without notice, for the purpose of product improvement.
Lecteur Etroit ARC1
Module OEM MA1
Notice d'installation
MA1-XY
MA1S-XY/PH5
MA1S-XY/BT1
B
Range: +9 Vdc to +15 Vdc
ARC1-XY: 130 mA
ARC1S-XY /PH5: 140 mA
MA1-XY: 130 mA
MA1S-XY /PH5: 140 mA
WURTH ELEKTRONIK
2
– Length 3.05m
Buzzer
" and "
" inputs of the reader's connector or controlled by the communication protocol of the reader (SSCP
: the reader will perform the operations configured with the configuration card.
TM
readers:
®
readers: 2 meters / 78.74 inch either plan.
Example: reference 74271222 WURTH ELEKTRONIK
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1110A10- Page 1 sur 6 - Ed. 06/04/2022
Lector Estrecho ARC1
Módulo OEM MA1
Procedimiento de instalación
conforme con
Product references
X:
1: TTL Output
3: RS485 Output
Power supply characteristics
Typical: 12 Vdc
ARC1S-XY /BT1: 150 mA
MA1S-XY /BT1: 150 mA
Characteristics
600624228220)
Buzzer / LED
Anti-tearing
protocol.
®
Read-only reader configuration
Powering-up the readers
: off; if no customer specific configuration).
TM
Caution for Bluetooth reader
TBLOCK option
Host
Precautions for installation
NOM-024 -SCFI-2013
Y:
A: cable
B: cable with connector
Connector Output cable
Wiegand Clock & Data RS485
4
Brown
5
Red
2
Grey
D0
1
Blue
6
Yellow
Clock
3
Green
8
Orange
7
White
0.94 in
.
US
FR
ES
Type
0 Vdc
+Vcc (+9 Vdc to +15 Vdc)
Code
NC
D1
Data
L+
Clock
L -
Led 1
Led 2
Buzzer
®
/ OSDP
TM
).
➔Reader