Installing the fan
The fan must be installed at a location on the ceiling sch that the blades are at least 2.3 m above the floor and 300 mm from
any object or wall. The mounting bracket must be attached to a ceiling structure that is capable of supporting a minimum of
30 kg using the two screws provided. At least 30 mm of the length of the screws must be screwed into the bracket.
WARNING!
SEE INSTALLATION STEPS AT THE END OF THIS MANUAL
EN

Remote control

Remote control safety functions
Blocking protection
The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds
after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the
obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue
to use the fan normally.
Note: Unless you remove the obstruction blocking the fan, it will not operate correctly.
Overload protection
If the fan's receiver detects that the motor is operating at greater than 80W (this indicates an overload), current to the
motor will be cut automatically, which will immediately stop the fan. To reset the receiver, press the off button on the remote
control.
Note: If the receiver goes into protection mode again, this may indicate a motor defect. Contact the supplier immediately.
The duration of the warranty is indicated in the warranty document provided in this manual.